Daily Inspection

Visual inspection:
1
Seal is undamaged.
The lid is closed and the handle is
locked.
There are no signs of cracks, holes
or other damages of more than 1.5
mm depth on the housing.
2
The indicator is dark blue in colour.
The oxygen self-rescuer may no
longer be used if there is a signifi-
cant loss of blue colour (50 % of the
particles have changed colour from dark blue to light blue or colour-
less).
Please contact Dräger if this is the case.

Assembly of Shoulder Strap

Oxy K 30 S/AS (GB) and Oxy K 50 S/AS (K+S/PL)
To prepare the oxygen self-rescuer for use, mount the shoulder strap as
shown:
Looping the shoulder strap into the
back plate of the housing
Loop the short end of the shoulder
strap into the slot in the housing's
back plate (1).
Looping the shoulder strap into the
adjusting buckle
Thread the ends of the shoulder
straps into the adjusting buckles
and pull the ends of the shoulder
straps as far as possible (2).
Close the adjusting buckles(3).

Using the Oxygen Self-Rescuer

Open the oxygen self-rescuer only in case of emergency.
If opened prematurely, the humidity of the ambient air could penetrate
the open oxygen self-rescuer and impair its function.
Inspect the oxygen self-rescuer daily.
Use the oxygen self-rescuer only once.
To avoid risk of fire, make sure that no flammable materials (petrol,
grease, solvents etc.) can get into the oxygen self-rescuer before or dur-
ing operation.
There is also danger of ignition if the oxygen-releasing chemicals come
into contact with combustible substances such as coal when the oxy-
gen self-rescuer is damaged.
Opened units are classified as used and it is not allowed to store them.
They have to be disposed of (see "Disposal" on page 12).
For routine training purposes, use the training unit
Oxy K 30 DT/ET, Oxy K 50 ST or Oxy K 50 ST (PL) (see "Order List" on
page 15).
1) not part of the EC type examination.

Donning Procedure

If incorrectly donned in cases of emergency, the oxygen self-rescuer could
2
start up with a delay.
When donning the unit, follow the described order of steps.
1
Oxy K 30 E
Opening the housing
1
Donning the unit
2
3
Oxy K 30 S/AS (GB) and Oxy K 50 S/AS (K+S/PL)
Opening the housing
Donning the unit
1)
Oxy K 30 ST,
Use the yellow grip to pull the unit
forwards.
Move the handle downwards until
the lid comes off of the oxygen self-
rescuer.
Remove lid.
Take hold of the neck strap with one
hand, then use your other hand to
take hold of the carrying frame
before pulling the oxygen self-res-
cuer upwards and out of the holder.
Turn the oxygen self-rescuer so that
the carrying frame faces the chest.
Pull the red rubber neck band over
your head and let it hang from the
back of your neck.
Adjust the neck strap to pull the oxy-
gen self-rescuer into the correct
position.
Take hold of the yellow opener.
Push the yellow opener away from
your body until lid separates from
the oxygen self-rescuer.
Pull the lid straight off of the oxygen
self-rescuer (away from your body).
Adjust the shoulder strap around
your neck.
Pull both shoulder straps as far as
they will go.
11