Installation Instructions

Step 1: Choosing Installation Type
The Vivente can be configured in 4 different ways:
Single-sided – Front glass only (see Fig 1a)
Two-sided Right (see Fig 1b)
Two-sided Left (see Fig 1c)
Three-sided (see Fig 1d).
The Vivente is supplied as a Three-sided configuration.
Please follow the steps below to adjust to your desired arrangement.
1. Remove front bottom trim on unit. See Fig. 2
2. On the desired side you wish to cover, remove side glass trim which is held in place by four
screws. Attach side panel in place of the side trim using the same four screws See Fig. 3A & 3B
3. For Front Glass Only setup, repeat Step 2 on the opposite side of product.
4. Assemble the appropriate front Trim to the product. (Three different trims are provided with the
product to facilitate the various setup options.) See Fig. 2
Step 2: Installing the Product
CAUTION: Two people will be required for various steps of this procedure.
This product is designed to be installed into existing block wall or a custom-built studded wall
structure. Please consult a competent installer before undertaking this to ensure a safe and
secure installation. If installing into an existing chimney or flue, please ensure that the chimney or
flue is blocked off. This is to prevent up-draughts affecting product operation.

Electrical Requirements

NOTE: A dedicated, properly fused 13 Amp circuit is required, rated for the appropriate voltage
(230-240V). An isolation switch should also be incorporated in cases where the product plug is
inaccessible after installation.
WARNING: Construction and wiring must comply with local building codes and other applicable
regulations to reduce the risk of fire, electric shock and injury to persons.
WARNING: To reduce the risk of fire, electric shock or injury to persons, always use a licensed
electrician.
1. Using the product dimensions (Fig. 11), build a suitable structure for the product to fit into.
Ensure that, when installed, the product is within 1m of a power outlet. Please refer to Electrical
Requirements section above for more details.
It is recommended that the base of the unit is installed between 200mm and 800mm from the
floor. This is to maintain an optimised viewing angle of the fire effect. (See Fig. 12)
The product must not bear the weight of the finished wall located above it. Consider the use of a
lintel for appropriate support.