Herunterladen Diese Seite drucken

MICRO-EPSILON wireSENSOR WPS-MK46 Montageanleitung Seite 2

Verfügbare Sprachen

Verfügbare Sprachen

Draw-Wire Displacement Sensors
Series WPS
Model
MK46
Assembly Instructions
wireSENSOR
Warnings
- Do not open the sensor housing.
- Do not let the measuring wire rewind without control (snap back).
- Avoid banging and knocking the sensor.
- Don' t let the power supply exceed the specified limits.
- Connect the power supply in accordance with the safety regulations for
electrical equipment.
- Fix the sensor with drawn in measuring wire to the target.
- Do not pull the measuring wire over range.
- Do not damage the measuring wire.
- Do not oil or grease the measuring wire.
- Do not bend the measuring wire.
- Do not pull the measuring wire at an angle.
- Do not allow to loop the measuring wire around objects.
- Do not loop the measuring wire around parts of the body.
Sensor Assembly
Mount the sensor through three screws M2.5 DIN 931 or mounting clamps.
The sensor does not have to be oriented in a special way. Prefer an installation
position with measuring wire outlet facing downwards if possible.
Choose the installation position so that damage and soiling of the measuring
wire is avoided.
Wire Guide and Fastening
If the measuring wire has to be extracted from the sensor to guide the wire resp.
to fix it to the target,
- the sensor may not be held by another person
- the measuring wire may not be further extracted but only to the specified
measuring range
- the surroundings of the sensor have to be protected against snapping of the
measuring wire
The measuring wire is fixed to the target using a wire clip. Fed the measuring
wire perpendicularly from the sensor housing. Misalignment only permissible
up to 3 degrees. If you drag of the measuring wire on the outlet hole or other
objects, this leads for damaging and/or snapping of the measuring wire. Keep
measuring wire in an area where it cannot be snagged or otherwise be violated.
Downloaded from
www.Manualslib.com
20
12.8
(.78)
(ø8
)
(.50)
Mounting hole
(.31)
2
(.07)
(ø4.5
)
(.17)
3x ø2.7
(.10)
ø3
(.11)
3.25
39.5
21
0.6
(1.55)
(.83)
(.13)
46
43.5
(.02)
(1.81)
(1.71)
Drawings WPS- ... -MK46, with incremental encoder,
dimensions in mm (inches)
12.8 (.50)
18 (.70) (WPS- 1000-MK46)
20 (.78) (WPS- 1250-MK46)
2 (.07)
Mounting
ø3 (.11)
hole 3x
ø2.7 (.10)
21
0,6
39.5 (1.56)
3.25
(.83)
(.02)
(.12)
46 (1.81)
42.5
(1.67)
Drawings WPS- ... -MK46, with potentiometer, dimensions in mm (inches)
manuals search engine
12.8 (.50)
18 (.70) (WPS- 1000-MK46)
Mounting
20 (.78)
(WPS- 1250-MK46)
Mounting clamp
hole 3x
Screw M3
ø2.7 (.10)
39.5 (1.56)
13
(.05)
3.25
58
(2.28)
(.12)
71 (2.80)
46 (1.81)
68
(2.68)
Drawings WPS- ... -MK46-CR, with potentiometer, voltage electronics, cur -
rent electronics and radial cable, dimensions in mm (inches)
Pin Assignment
Electrical
Output
Connection
-CR-Integral
-U- Voltage
-I- Current
cable
-P- Potentiometer
white
Power supply
Power supply
brown
GND
green
Signal
58 (2.28)
yellow
GND
68 (2.68)
All potentiometers must only be used in a voltage divider circuit. Using
them as a variable resistor, destroys the element. Ensure that the maximum
current through the viper is limited for sensors with hybrid potentiometer.
Note the pin assignment for draw-wire displacement sensors with enco-
der output (E). The sensor contains an additional supplement for detailed
information.
2 (.07)
Declaration of incorporation according to the EC Machinery Directive
ø3 (.11)
2006/42/EC, Annex II B
Manufacturer and authorized representative for the compilation of the rele-
vant technical documents
MICRO-EPSILON MESSTECHNIK GmbH & Co. KG
Königbacher Straße 15, 94496 Ortenburg / Germany
hereby declares that the machine designated below, as a result of its man-
ner of design, construction as well as version that has been placed on the
market - to the extent possible in the scope of delivery - corresponds to the
relevant, fundamental health and safety requirements of the EC Machinery
21 (.83) 0.6
58 (2.28)
Directive, including the valid changes at the time of this declaration.
(.02)
68 (2.68)
Model:
Type designation:
The following fundamental health and safety requirements in accordance
with Annex I of the above-named directive are applied and maintained:
- No. 1.1.2. Principles of safety integration
- No. 1.7.3. Marking of machinery
- No. 1.7.4. Instructions
Furthermore, the compliance with the following standards is explained,
including the valid changes at the time of this declaration:
- EN ISO 13857 Safety of machinery - Safety distances to prevent hazard
Use all potentiometers
zones being reached by upper and lower limbs
only in a voltage divider
- EN 60204-1: 2006/A1: 2009 Safety of machinery - Electrical equipment
circuit. Using them
of machines - Part 1: General requirements
as a variable resistor,
- DIN EN 61326-1: 2013
destroys the element.
- DIN EN 61326-2-3: 2013
Ensure that the maxi-
Moreover, we declare that the relevant technical documentation for this
mum current through
partly completed machinery has been created in accordance with part B of
GND
Annex VII, and that we shall be obligated to deliver these upon the request
the viper is limited for
of the market surveillance authorities.
sensors with hybrid
---
The described partly completed machinery is intended for installation in
potentiometer.
a production line. The commissioning of this partly completed machinery
---
shall be prohibited until the partly completed machinery has been installed
in a machine that complies with the provision of the EC Machinery Directive
and for which an EC Declaration of Conformity in accordance with Annex II
A is available.
Ortenburg, October 8th 2015
Declaration of incorporation
wiresensor
WDS-xxx, WPS-xxx
Dr. Thomas Wisspeintner
Managing Director
loading