Also, check again to ensure the rope functions properly and stops and blocks
correctly.
To be totally safe only use connectors European reference: EN 362.
IX. THE APPARATUS MUST BE IMMEDIATELY WITHDRAWN FROM
CIRCULATION IF......
.....there are doubts about the safety system.
.....when during a check-up or for any other reason the fall arrest device shows signs
of damage through a knock or other cause of malfunction, it is imperative to put the
apparatus out of service and attach a label to that effect. Then the apparatus should
be sent to a center authorized by a manufacture for repair.
.....it has been used for arresting a fall, remove from use and get a competent person
to give another check-up.
X. ANCHORAGE POINT REQUIREMENTS
Never work above the fall arrest device or under an anchorage point.
The fall arrest device must be placed vertically at least two meters above the work
place of the person attached by the dorsal, sternum, or ventral attachment on his
harness.
The anchorage point must be completely clear of any obstacle which could
jeopardize the smooth functioning of the fall arrest device.
The choice and fixing of the anchorage point is the responsibility of the site manager
or specialized firm.
XI. INSTRUCTIONS FOR LINKING UP TO THE ANCHORAGE POINT
Install the anchorage point as explained in section X.
Link up the fall arrest device to the anchorage point with a connector complying with
European standard EN 362 or with a sling or strap complying with European
standards or alternatively with steel cable capable of withstanding a minimum charge
of 2000 kilos.
XII. INSTRUCTIONS FOR LINKING UP THE ANCHORAGE POINT TO THE
HARNESS
Always be careful to link up the RODEOSTOP B100 safety system by means of the
dorsal, sternum or ventral connector on the harness.