Commissioning / operation
6.2.2

Set-up

You use the 'Set-Up' menu to set up the unit operated using the control PCB.
Basic settings such as dishwasher type, detergent and rinse aid products used
(solid, liquid), and the use of release signals are set in this process.
When installing a complete unit, the system is already preset.
Only the dishwasher type and release signals still need to be configured.
Rinse aid
In the 'Rinse aid setup' (113), the rinse aid used is configured and set whether the rinse
temperature is measured or not.
Depending on the rinse aid used, the following settings can be made on the EcoPlus
PDRX:
- Liquid product via peristaltic pump (versions SDR-ST and SDRX)
- Capsule
The following detergent must be configured for the use of the SMARTPOWER
Dispenser:
- Capsule
You can also set the following:
- The boiler temperature is measured and displayed
- No temperature sensor configured to show boiler temperature
Release signals
The 'Enable Signals Set-Up' screen (114) is used to configure enable signals that are
sent from dishwasher modules to the controller PCB.
If enable signals are configured, the SMARTPOWER
until the corresponding enable signal is present to deliver the metered quantity.
You can configure the following sharing signals:
- Pre-dose
- Wash
- Rinse
If no input is activated, the corresponding dosage starts as soon as the voltage
is applied.