If the signal is too weak, have the conductor pass through the probe twice. Do not forget to divide the
measured value by two in this case.
To view the instantaneous signal, set the switch to INST. To view the RMS signal, set the switch to RMS.
Carefully check that the red OL indicator is off. If it is lit, it means that the current to be measured is too
great. Remove the conductor from the probe in this case.
2.2.2. DISCONNECTION
„ When the measurement is over, press the trigger to open the probe and withdraw the conductor.
„ Disconnect the probe from the oscilloscope.
„ Power down the probe by setting the switch to OFF.
30
I
Chapter II
Oscilloscope current probe