Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
Installation of the mirror ball motor and the mirror ball
Please consider the EN 60598-2-17 and the respective national norms during the
installation! The installation must only be carried out by an authorized dealer!
The installation of the mirror ball has to be built and constructed in a way that it can hold 10 times the weight
for 1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert before taking into operation for the first time and after changes before taking into operation another
time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a
skilled person once a year.
Attachment
The rotary motor should be installed outside areas where persons may walk by or be seated.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to)
calculating working load limits, installation material being used, and periodic safety inspection of all
installation material and the mirror ball. If you lack these qualifications, do not attempt the installation
yourself, but instead use a professional structural rigger. Improper installation can result in bodily injury
and/or damage to property.
The motor must only be installed in an absolutely horizontal position at a vibration-free, oscilation-free and
fire-resistant location. By using a water-level, make sure that the motor is installed absolutely horizontally
and that the motor axle points exactly to the bottom.
The motor and the mirror ball have to be installed out of the reach of people.
If the motor shall be lowered from the ceiling or high joists, professional trussing systems have to be used.
The motor must never be fixed swinging freely in the room.
Caution: Mirror balls may cause severe injuries when crashing down! If you have doubts concerning the
safety of a possible installation, do NOT install the motor!
International
L
N
DANGER TO LIFE!
16/19