Important safety notes:
Make sure, that all of the followin g safety rules are fulfilled.
The device must only be installed by qualified personnel to make sure all
applicable safety rules are fulfilled. Additional safety rules and legal
restrictions may apply depending on the country of operation.
•
Risk of electric shock!
Lethal high voltage is present inside the unit and at the terminals. Due to high voltage storage devices lethal voltages may be present inside the unit
and at the terminals if the unit is switched off or disconnected from supply voltage.
•
The unit must not be operated if there is any damage (e.g. mechanical damage after transport).
•
The electrical part is intended for use in dry and chemically and biologically inactive environment only. Keep water and humidity away from the
whole electrical assembly. Lethal voltages across the complete system can result from contact between lamp and water. A separate protective
earthing of the complete system is mandatory.
•
Disconnect unit from mains before any maintenance operation.
Dangerous voltage may be present inside the unit energy storage devices even if the unit is disconnected from mains.
Wait at least 10 minutes after disconnecting the unit from mains voltage before starting any service actions.
•
Repeated rapid switching might lead to a fault. Do not turn off and on the unit within less than 10 seconds.
•
During ballast section start up, in case of lamp defects or due to wrong lamp wiring high voltages up to 1200Veff may occur at the lamp terminals.
This high voltage may be present for a couple of milliseconds until the internal protection circuits shuts down the ballast. At each ballast restart,
after any temporary disconnection from mains voltage, the ballast will try to ignite the lamp once more, so again, high voltages may occur.
•
The ballast does not provide galvanic insulation from mains at the lamp terminals.
•
Harmful voltage occurs at the lamp terminals even if the ballast is in standby mode and the lamps are switched off.
•
Never cut the lamp wires while the ballast is in operation. Risk of serious injury or death!
• The load for the fault detecting contacts has to be kept within the limits specified in the datasheet. It is recommended to use parallel operation of
contacts instead of serial operation in case of summarizing fault detection.
This device produces harmful radiation. Direct contact can pose a hazard to eyes and skin. Only check the operation of the UV-C lamp through trans-
parent parts of the tank, never in direct contact.
•
Warning - Due to the risk of injury, this product is not suitable for use by children or persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience or knowledge, unless they are supervised or instructed on the use of the device by a person responsible
for their safety.
• Warning - Risk of electric shock. If in doubt as to whether you have sufficient knowledge and experience, this device must always be connected by
a
certified electrician, according to the locally applicable standards and laws, with a properly earthed connection protected by a residual-current
device.
•
Warning - To reduce the risk of electric shock, a damaged cable should be replaced immediately if possible.
•
Warning - To reduce the risk of electric shock, the use of an extension lead is not recommended. Connect the device to an easily accessible mains
outlet.
•
Do not bury the connection lead. Never share connections and/or connection leads with lawn mowers, hedge trimmers or other equipment.
• During and after commissioning, the unit is operating and filled with water. Therefore, to reduce the risk of electric shock,
be careful during repairs and/or service work. If you lack the necessary knowledge and experience, repair and/or service activities should be
performed by authorized/accredited technicians.
• Disconnect the connection lead first, before removing the unit from the water.
•
The device must not be switched on if it has been damaged during or as a result of transport, a fall, a production defect or other cause (particularly
the quartz glass sleeve and the UV-C bulb).
•
Always connect the device to an undamaged, earthed mains outlet with hinged cover.
•
Always remove the plug from the outlet when the device is not in use and/or during cleaning and maintenance activities. The plug must be removed
from the mains outlet by pulling on the plug itself. Never pull on the lead to remove the plug from the outlet.
•
To reduce the risk of electric shock, the plug must not be inserted into or removed from the mains outlet with wet hands and/or while you are
standing in the water.
•
The connection lead of the appliance may not be shortened and/or connected directly without a plug. If the lead becomes damaged, the entire
device must be submitted to authorized/accredited technicians. Devices with cut-off/shortened cables are excluded from warranty coverage.
•
After the device is switched off the bulb will remain warm for ten minutes.
•
Use of the equipment for any purpose other than that for which it was designed or developed is not permitted. Use of the equipment for a purpose
other than that for which it was developed by the manufacturer may lead to unsafe situations.
•
If there is a seasonal risk of freezing of the device, or parts thereof, appropriate measures must be taken to prevent freezing damage. Damage
caused by freezing is always excluded from warranty coverage.
•
Devices with a stainless steel housing are not suitable for water with a high salt content. If the salt content is too high, the steel can oxidize and
damage the housing.
• The unit should never be placed downstream of a heat exchanger or other heating source. If the bulb is not cooled by the water sufficiently, it may
be damaged.
•
This device may only be used in accordance with the guidelines described in this manual. You must also adhere to the instructions provided on the
device.
•
Unintended use of the device or damage to the housing can lead to the escape of harmful UV-C radiation. Exposure to UV-C radiation, even in
small doses, cause damage to the eyes and skin.
•
If you intend to use of the device in combination with chemicals and/or medications, always consult the manual(s) for this/these product(s). Pay
particular attention to the safety instructions.
• It is not permitted to flow an aggressive liquid through the reactor or add additives to the treated water which may have a negative effect on
corrosion or degradation of the materials that are used. This to prevent dangerous situations and damage to the reactor and surrounding
installations and / or flora and fauna.