Herunterladen Inhalt Inhalt Diese Seite drucken

Tips And Help; Fault Report - Autool Svb208 Übersetzung Der Originalanleitung

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

TIPS AND HELP

Fault report

Fault
Symptoms
No power
Automatic
shutdown
TF card error
Unable to
charge
Blurry image
Probe
articulating
range too small
TF card
recording
failure
Cause Analysis
Insufficient
battery voltage
Insufficient battery
level/ Auto
power-off setting
enabled
TF card not
properly installed
Charging port is
dirty or charging
cable is damaged
Lens is dirty /
Object being
inspected is out of
the probe's depth
of field range /
High temperature
causing lens
damage
Flexible hose
twisted or
deformed
Insufficient TF
card capacity
10
Solution
Charge the borescope
Charge the borescope
and disable the auto
power-off setting
Reinstall the TF card
Replace the
charging cable
Use a cleaning cloth to
wipe the lens clean /
Ensure the probe is
placed within 15-100mm
of the inspection area /
Use the probe in an
environment below 70°C
Ensure the flexible
hose is placed
straight before use
Replace the TF card
or clear the files

Kapitel