Item no. 1243798
Intended use
The entry alarm is designed to monitor windows or doors. A magnetic contact triggers
an alarm when the door or window is opened and the device emits a loud alarm tone.
Power is supplied via three button cell batteries.
For safety and approval purposes (CE), you must not rebuild and/or modify this product.
If you use the product for purposes other than those described above, the product may
be damaged. In addition, improper use can cause hazards such as short circuiting,
fire, electric shock etc. Read the instructions carefully and keep them. Make this
product available to third parties only together with its operating instructions.
This product complies with the statutory national and European requirements. All
company names and product names are trademarks of their respective owners. All
rights reserved.
Delivery content
• Entry alarm
• Magnet
• 3 x button cell (LR44)
• Operating instructions
Safety instructions
Read the operating instructions carefully and especially observe the safety
information. If you do not follow the safety instructions and information on
proper handling in this manual, we assume no liability for any resulting
personal injury or damage to property. Such cases will invalidate the
warranty/guarantee.
• The device is not a toy. Keep it out of the reach of children and pets.
• Do not leave packaging material lying around carelessly. These may
become dangerous playing material for children.
• Protect the product from extreme temperatures, direct sunlight, strong
jolts, high humidity, moisture, flammable gases, vapours and solvents.
• Do not place the product under any mechanical stress.
• If it is no longer possible to operate the product safely, take it out of
operation and protect it from any accidental use. Safe operation can no
longer be guaranteed if the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions or
- has been subjected to any serious transport-related stresses.
• Please handle the product carefully. Jolts, impacts or a fall even from a
low height can damage the product.
• The product must only be mounted and used in dry, enclosed indoor
areas. The product must not become damp or wet.
• Do not install the product on the side of a window or a door which is
exposed to moisture.
• The product emits a loud alarm tone when activated. In some countries
there are regulations governing the volume or the duration of the alarm
tone. Pay attention to any local regulations.
• Correct polarity must be observed while inserting the batteries.
• Batteries should be removed from the device if it is not used for a long
period of time to avoid damage through leaking. Leaking or damaged
batteries might cause acid burns when in contact with skin, therefore use
suitable protective gloves to handle corrupted batteries.
• Batteries must be kept out of reach of children. Do not leave batteries
lying around, as there is risk, that children or pets swallow them.
• All batteries should be replaced at the same time. Mixing old and new
batteries in the device can lead to battery leakage and device damage.
• Batteries must not be dismantled, short-circuited or thrown into fire.
Never recharge non-rechargeable batteries. There is a risk of explosion!
• Consult an expert when in doubt about operation, safety or connection of
the device.
• Maintenance, modifications and repairs are to be performed exclusively
by an expert or at a qualified shop.
• If you have questions which remain unanswered by these operating
instructions, contact our technical support service or other technical
personnel.
Operating elements
1
3
2
4
5
Operation
a) Inserting batteries
• Move the On/off switch (5) to the OFF position.
• Remove the front cover of the entry alarm by moving the OPEN housing lock (1) in
the direction of the arrow shown. Ensure that you do not damage the connection
cables to the built-in loudspeaker.
• Insert three Type LR44 batteries with correct polarity into the battery compartment
(3) (observe plus/+ and minus/-).
• Replace the front cover after inserting the batteries. Move the OPEN housing lock in
the opposite direction of the arrow to lock it into place.
The batteries must be changed when the entry alarm becomes very quiet or
when it no longer functions.
b) Preparation for mounting
• The magnet (2) can be mounted either to the left or right of the entry alarm. Adjust
the sensor position (4) in the entry alarm accordingly.
• The sensor is installed on the right side of the entry alarm by default. In order to
use the left-hand side, open the front cover as described in the "Inserting batteries"
section.
• Carefully remove the sensor, which includes insulation and is attached to two
cables. Then reinsert it on the left-hand side.
• Replace the front cover after changing the position. Ensure that a cable does not get
caught by accident when closing the front cover.
c) Mounting
Refer to the "Preparation for mounting" section.
• The entry alarm and the magnet (2) can be stuck to a smooth and clean surface free
from grease and dust.
• Turn off the entry alarm using the on/off switch (5).
• Remove the protective film from the adhesive pad on the rear side and press the
entry alarm and magnet firmly into place.
• The distance between the magnetic contact in the entry alarm and the magnet
should not be greater than 8 mm in order to ensure that the alarm functions properly.
• Secure the magnet to the side where the sensor in the entry alarm is located. Note
the orientation of the arrow markings on the entry alarm and the magnet. One of
the arrows on the magnet must point directly at the arrow to the left or right of the
entry alarm.
d) Activating and turning off the alarm
• Turn on the entry alarm using the on/off switch (5).
• You will hear a short beep tone. The alarm function is now activated. When the door
or window is opened, a loud alarm sounds for about 30 seconds.
• Turn off the entry alarm before the 30 seconds have passed using the on/off switch.
• To deactivate the alarm, turn off the entry alarm using the on/off switch. Access
is no longer secure and the door/window can be opened without an alarm signal
sounding.