Manual cleaning (A-Cleaner)
The vibration function (switch setting RA /switch (2a) should be activated at
the latest when the volume flow display (2c) (warning lamp) lights up or
when the warning signal sounds or when the suction output sinks.
Automatic cleaning (A-Cleaner)
Filter cleaning is performed (switch setting RA/switch (2a) automatically
during the next working break when the minimum volume flow level is
reached.
Permanent filter cleaning (M-Cleaner)
The vacuum cleaner DSS 35 M iP is fitted with an electromagnetic filter
cleaning unit which can be used to shake the dust off the folding filter
cassettes. The folding filter cassettes are cleaned alternately so that
continuous working can be guaranteed.
Emptying the tank
Only permitted with dusts with AGW's > 1mg/m
Switch off (2a), disconnect plug, open snap locks (9). Take top section (1)
and suction hose from the tank (6). Empty the tank.
Fleece filter bag
To insert or remove the filter bag/emptying bag, remove the top section (1).
To do this, open the side locks (9).
Only use the paper filter bag for dry suctioning.
Inserting the fleece filter bag
25 and 50 litre tank on DSS 20 A and DSS 50 A
Push the flange over the suction opening
35 l special tank on DSS 35 M iP
Turn the knob in the suction opening with the marking
Push the flange over the suction opening.
(4)
Operating the slide valve:
Push the slide valve from inside to the outside
(1), turn by 180° (2) (see marking (4) and
press from outside through the suction pipes
to the inside again (3).
24
a
.
4 to the top.