Addresses should be assigned beginning with "0".
Connect the microphones and the DMI-8.
Connect the GN outputs of the DMI-8s in rising or-
der of their device addresses to the GN inputs of
the MCA-ES to keep RCS remote control and rout-
ing in the same sequence of channels.
Connect the Word Clock output of the MCA-ES
via BNC cable to the Word Clock input of the cas-
caded DMI-8 to synchronize the DMI-8s and con-
nected microphones to the MCA-ES word clock.
Connect the DMI-8s to the power supply system
and start the RCS soft ware.
Attention: The DMI-8 must be switched on before
the RCS is started so that the DMI-8 will be de-
tected by the PC or Mac. Alternatively, the com-
mand Options/DMI can be used to detect a DMI.
Ensure correct fastening of the connectors when
connecting the cables.
Lay the cables in such a way that they do not pres-
ent a tripping hazard.
Updating of fi rmware
The fi rmware in the MCA-ES, in the DMI-8 and in
the Neumann microphones is updatable. Updates
can be performed without opening the equip-
ment, via the RCS control soft ware (see the RCS
Operating Manual).
6.
Technical data
Permissible atmospheric conditions
Operating temperature .....................0 °C to +45 °C
Storage temperature .....................–20 °C to +70 °C
Relative humidity ................... max. 90 % at +20 °C
Ethersound ports IN/OUT ........................ 2x RJ 45
frequencies of 44.1/48 kHz by the
included Auvitran Ethersound module
(higher sampling frequencies
GN inputs .................................................... 8x RJ 45
44.1 / 48 / 88.2 / 96 / 176.4 / 192 kHz
and power supply for the MCA-ES
MCA-ES
Synchronization ................................automatically
or as primary master of the network
to an external word clock or AES11 signal,
if present, otherwise the internal
word clock generator is activated.
Word clock (or AES11) input ............................BNC
Vin ....................................... >100 mV at 75 ohms
Word clock (or AES11) output ...........................BNC
Vout ..............................approx. 1.5 V at 75 ohms
(internal word clock generator)
Internal word clock
generator: ...................... 44.1 / 48 / 88.2 / 96 kHz/
Indicators:.................... Power, ES Network Status,
Ext Word Clock, Word Clock Frequency,
Control bus:......................................2 x RJ 45 ports;
connection to the DMI-8 respectively
the computer USB port via the
Neumann USB 485 interface converter;
power-out pin (approx. +11.3 V,
1)
All values are for non-condensing humidity.
1)
ES100 is limited to sampling
on request).
DMI-8 audio data using
sample frequencies of
to the Ethersound network
connected to the IN port
176.4 / 192 kHz
Accuracy ±25 ppm
Valid GN 1..8
connected in parallel
for the purpose of cascading.
RS 485 with additional
max. 500 mA)
EN