Commissioning
Select the time zone from the Time zone list field.
5.
Click Save > OK > Reboot now > OK.
6.
Security Settings
Open the Configuration > Security page.
1.
Enter the current password in the Current Password entry
2.
field.
Enter a new user name in the New username entry field.
3.
Enter a new password in the New password entry field.
4.
Then enter the new password again in the New password
5.
again entry field.
Click Save > OK.
6.
SIP Settings
–
Knowledge of the DECT handset data:
Internal number, password (entered in the PBX)
Open the Configuration > SIP page.
1.
Under General, enter the number of the SIP port in the Local
2.
port entry field.
Note: The standard port 5060 is already set up. Configure the
port according to the port configuration in the PBX.
Enter the PBX's IP address in the Default domain entry
3.
field.
Select the codec priority in the Codec priority list fields.
4.
Note: During operation on Auerswald PBXs, we recommend the
following codec priority configuration:
1: PCMA/8000 (G.711 A-law)
2-6: None
During operation on PBXs from other manufacturers, configure
the codec priority according to the available codecs.
Click Save > OK.
5.
Configuring a DECT Handset
Requirements
–
Knowledge of the DECT handset data:
26
COMfortel WS-400 IP - Instructions V05 06/2017