Besides the time, the LCD display also shows a cursor
beneath the digits. The CURSOR < and CU RSOR
> keys in the SETUP field can be used to move the
cursor. The SETUP +/—keys change the programmed
time.
The printer's realtime clock may be programmed
be accurate to the second. To do so, preset the clock
to a time slightly ahead of the current time (e.g. one
minute
ahead). Wait until the set time is reached,
then immediately press one of the MODE buttons to
exit this
function
and start
10: SET
DATE
For setting the current date in the format DD-MM (day
- month).
Besides the date, the LCD display also shows a cursor
_
beneath the digits. The CURSOR < and CURSOR
> keys in the SETUP field can be used to move the
cursor. The SETUP +/- keys change the programmed
date.
Illegal values, e.g. 32 07, are rejected and an audible
and visible warning signal is given.
11: SET
YEAR
For setting the current year in the format 19xx.
Besides the year, the LCD display also shows a cursor
" _ ") beneath the digits. The CURSOR < and CURSOR
> keys in the SETUP field can be used to move the
cursor. The SETUP +/—keys change the programmed
year.
The year will be automatically advanced to 2000 when
the
time
comes.
SCOPE
SET
1: ZOOMRANGE
For setting
the zoom range (X magnification)
Channels 1 and 2. The setting "0-9, 0-9" causes the
entire contents of the scope's memory to be printed
out without
magnification
setting).
The LCD display shows the range to be printed for
each
channel
and a cursor
CURSOR < and CURSOR > keys in the SETUP field
can be used to move the cursor. The SETUP +/— keys
then change the zoom range. The digits refer to the 10
graticule divisions of the scope's CRTscreen, and are
numbered from Oto 9 (from left to right). The first digit
Subject to change without notice
to
and
the clock.
for
of either channel (default
'
below the digits. The
sets the leftmost
division and the second digit the
rightmost division of the range to be printed, referring
to the unzoomed scope screen image. The zoom range
can be separately set for each channel.
Example: the setting CHI 0-0, CH2 3-6 will cause the
signal from Channel 1 depicted in the division at the far
left of the screen graticule to be printed in expanded
(magnified) form over the entire width of the printout
(10 divisions). At the same time, division 3, 4, 5 and 6
are also magnified and printed over 10 divisions. The
zoom settings are documented
unless it has been suppressed.
If a type HM408 oscilloscope is connected to the
Graphic Printer and if furthermore
function
is enabled
function
is deactivated.
2: ZOOM
CURSOR
In order to use this function,
readout
and cursor functions
has been enabled using the SETUP +/—keys (switched
ON), then the section between
(delta t and f measurement)
Yt mode and stored in the scope's memory is printed
out, magnified over all 10 divisions of the printout.
Printouts
with
ZOOM
parameter field with "ZOOM f(CURSOR)"
3: TIME/DIV.
Here a time deflection coefficient
can be called up by the user on the Graphic Printer
using the
SETUP +/— keys. The time
coefficient
can then be printed out in the parameter
field. If the setting is such that no TIME/DIV. coefficient
is displayed,
then there
parameter field of the printout either.
If the Graphic Printer is connected to an HM408, then
the TIME/DIV. coefficient
read in by the Graphic Printer and printed out. The
setting
performed
manually
unchanged, but is ignored.
4: VOLT/DIV
CHI 12
For entering
the vertical deflection
scope channels I and II.
Besides the vertical deflection
display shows a cursor
CURSOR
< and
CURSOR
Channel I or Channel II. Then use the SETUP +/—keys
to set the VOLT/DIV. coefficients
in the parameter field
the ZOOM CU RSOR
(ON), then the ZOOMRANGE
the scope must have
(HM408).
If this function
the vertical cursor lines
of a waveform
captured in
CURSOR
are documents
read from the scope
deflection
will be no output
transmitted
by the scope is
by the
user remains
coefficients
coefficients,
the LCD
beneath the digits. The
> can be used
to select
to match the scope
ENGLISH
in the
in the
for
• 9