Seite 1
HAD84052781C8 Service Manual Cassette Deck RS-B48R dbx/Dolby B-c NR, Auto-Reverse Cassette Deck Color DOLBY (K)...Black Type .Silver Type Color Area .AII European areas except United Kingdom. [B]..United Kingdom..Asia, Latin America, Middle East Africa areas. Australia. RS.8R MECHANISM SERIES...
Seite 2
RS-B48R CONTENTS ITEM PAGE ITEM PAGE • Schematic Diagram • Location of Controls and Components • Electrical Parts List • Disassembly Instructions • Replacing Rotary Head Assembly • Circuit Boards and Wiring Connection Diagram • Mechanical Parts Location (included Parts List) •...
Seite 3
RS.B48R DISASSEMBLY INSTRUCTIONS Fig • 2 The head azimuth can be adjusted by removing the cassette lid. Fig. I MAIN P.B. Fig. 4 Fig. 3 Fig. 5 (H) How to remove flat cable F'atcable White line Open the lid of connector in the direction of the arrow...
Seite 4
RS.B48R N(ETER BOARD FL METER Fig. 9 Fig. 8 MODE Shown remove —. Remove — Ref. Procedure fig. — • 2 ornament screws ..• 3 screws Case cover • As shown in fig. 1, pull case cover in the direction of arrow .....(C)
Seite 5
RS.B48R Reassembling the Mechanism Unit MECHANISM Extension UNIT Cord 1. For repair, measurement or adjustment with mechanism removed from the unit be sure to ground the lower base plate of the mechanism. grounding, connect extension cord mechanism's lower base plate and the lug terminal Terminal from amplifier printed...
Seite 6
RS.B48R Set switches and controls in the following positions, unless otherwise specified. NOTES: • Balance control: Center • NR switch: • Make sure heads are clean • Make sure capstan and pressure roller are clean • Timer start switch: OFF •...
Seite 7
RS-B48R Checking the difference in level between forward and reverse running 15. Reproduce the playback level adjustment signal (315 Hz at OdB) on the standard playback adjustment tape; and check that the difference between the level in forward running and that in reverse running is within 1.0dB.
Seite 8
RS-B48R @ Playback frequency Equipment Condition: • VTVM • Playback mode response • Oscilloscope (Forward . Reverse) • Test tape...QZZCFM • Normal tape mode Test equipment connection is shown in fig. 5. Playback the frequency response portion of test tape (QZZCFM).
Seite 9
RS-B48R @ Overallfrequency Condition Equipment: response • Record/playback mode • VTVM • Test tape • Normal tape mode • ATT (reference blank tape) • Croa tape mode • AF oscillator ...QZZCRA Normal • Metal tape mode • Oscilloscope .QZZCRX for croz •...
Seite 10
RS.B48R Overall gain Equipment: Condition • Record/playback mode • VTVM oscillator • ATT • Oscilloscope • Normal tape mode • Input level controls...MAX • Resistor (600Q) • Test tape • Standard input level; (reference blank tape) ....-72±4dB ..QZZCRA Normal LINE ...-24±4dB Test equipment connection...
RS.B48R Input scanning time Condition: Equipment: adjustment • Stop mode • Oscilloscope 1. Place the recorder in the stop mode. 2. Connect an oscilloscope to pin 31 of IC204,as shown in Fig. 21. 3. If the measured value is not within standard value, correct it by opening or closing the jumper junctions A, and B as follows (See Fig.
Seite 12
RS.B48R MICROCOMPUTER TERMINAL FUNCTION WAVEFORM (IC204: MN1405RMS) Terminal Function/operation Symbol Name • "High" level with music select at ON COII Music select (M.S) command level with biank skip at ON. COIO Blank skip • ' 'High" (B.S) command level with music repeat at ON...
Seite 13
RS.B48R RS.B48R Terminal Terminal Symbol Name Function/operation Symbol Name Function/operation BLOCK FF/REW motor PLAY PAUSE indication • "High" level concurrently with PAUSE command. LINE rotation select 'High" level during: output (FFIREW motor PAUSE command rotation command) MICRONONE JACK • "High" FF and level during FF and...
Seite 14
RS.B48R RS.B48R BLOCK DIAGRAM DOLBY-C DOLBY-B DOLBY-C Cr02 N4ETAL Sl-2 S2-l S3-l S2-2 S3-2 S201-2 S202-2 LINE METER Irvut Level Control MICRONONE JACK 0220 Q 233 IC501 METER DRIVE DOLBY NR AMP LINE IC7 AMP 0223 set/ Reset Øntr01 EMITTER 0502 0503 PB.EQ...
RS.B48R NOTES: EQUIVALENT CIRCUIT • Sl.l, Sl.2 . D01bY.CINIOUT switch (shown in OUT position). • S2-1, S2-2 : Dolby-B IN/OUT switch (shown in OUT position). IC501 : AN6870N : dbx "Tape" IN/OUT switch (shown in OUT position). • S201-1rvS201-4 : Auto tape select switch (for Cr02).
Seite 18
RS.B48R Ref. No. Part No. Part Name & Description Ref. Ref. No. Part Ref. No. Part No. Ref. Part Part ECCDIH391K Q 204 2SD12650 R 185, 186 ERD25FJ103 R 343 ERD25FJ102 c 133, 134 COILS R 187 , 188 ERD25FJ272 ERD25FJ222 c 135 ECEAIHUROIO...
Seite 19
CIRCUIT BOARDS WIRING CONNECTION DIAGRAM PHOTO SENSOR * For mark areas. MAIN CIRCUIT BOARD T p 10 NYLON COUPLE Clock pulse Clock pulse adjustment point (B) TP202 adjustment point NYLON COUPLE AC POWER CORD _—-223 0205 E212 0203 IDIBKAI R2Z7 C901: SPARK C112.4 KILLER...
Seite 20
RS.B48R TERMINATIONS * For B] mark areas. NYLON COUPLER NYLON COUPLER * For mark areas. AC POWER CORD NYLON COUPLER L 8t'J BRIN ICI, 2, 6—8, 201 C901 . spARK IC202, 203 IC3, 4, 501 IC204 301, 302 KILLER S902: AC POWER NYLON COUPLER...
Seite 21
RS-B48R RS.B48R • MECHANICAL PARTS LOCATION • CABINE NOTES: (860 X-PROFILE APPLY FITTING FLYWHEEL BELT D ..For all Europe AK.152 COATING 1. First load the capstan belt via the belt rest, as shown in the figure below. United Kingdo 2. Install the capstan motor assembly and then .For United...
Seite 22
RS.B48R RS.B48R • CABINET PARTS LOCATION REPLACEMENT PARTS LIST Important safety notice NOTES: Components identified mark have special ...For all European areas except Characteristics important for safety. When replacing any Of these components, United Kingdom. only manufacturer's specified parts. For United Kingdom. Areas ..
Seite 23
RS-B48R [Original (for [N] mark areas)] and RS-B48R for PX. PARTS COMPARISON TABLE: Please revise the original parts list in the Service Manual RS-B48R (for [NI mark areas) to conform to the changes shown herein. If new part numbers are shown, be sure to use them when ordering parts.
Seite 24
Placer la plaque sur le mécanisme. d'entretien du modéle No. RS-B48R. Régler le mécanisme sur le mode PLAY. Placer la tige de contröle aur la plaque. Passer la tige de contröle dans chaque guide de bande.
Seite 25
@ Réponse en fréquence Condition: Equipement: Reproduire le signal de 8kHz (315Hz å OdB) de la Cassette étalon standard, et vérifier que la différence å la lecture •Mode de lecture • Voltmétre électronique niveau entre les modes de lecture avant et lecture inverse ne dépasse pas 1dB. (En avant •En sens inverse) •...
Seite 26
@ Répons de fréquence Condition: Equipement: Gain global Condition: Equipement: Lire la ten globale • Mode enregistrement/ lecture • Voltmétre électronique •Voltmétre éiectronique • Mode d'enregistrement/lecture • Mode de bande normale • A tténuateur •Oscillateur • Mode de bande normale Vale •...
Seite 27
Gain global Condition: Equipement: Lire la tension indiquée sur le voltmétre CC. • Mode d'enregistrement/lecture •Voltmétre électronique •Mode de bande normale •Oscillateur Valeur de référence: 15±0,5mV •Contröles de niveau d'entrée •Atténuateur .MAX •Oscilloscope Si la valeur lue ne correspond pas la valeur de référence, régler VR7 (emplacement indiqué...
Seite 28
Rückwärts- und Vorwärtslauf innerhalb von 1,0dB befindet. 16. Nach erfolgter Justierung sind die Bandführungs.Höhen- und -Winkeljustierschrauben zu sichern. RS-B48R DEUTSCH Tonkopfhöheneinstellung durch Verwendung der Tonkopfeinstellungsschablonc (QZZ0207) Die Tonkopfeinstellungsschablone erlaubt genaues und schnelles Einstellen der Tonkopfhöhe in folgender Verwenden Sie bitte diese Broschüre...
Seite 29
@ Frequenzgang Bedingung: Meßgerät: Das Playback Pegelsignal (315kHz bei OdB) auf dem Standerd Playback MeBband wiedergeben und prüfen, Wiedergabe •Wiedergabe • Röhrenvoltmeter daB sich die Pegelabweichung bei Rückwärts. und Vorwärtslauf innerhalb von 1,0dB befindet. (Vorlauf-Rücklauf) •Oszillograph Nach erfolgter Justierung sind die Bandführungs-Höhen- und -Winkeljustierschrauben zu sichern.
Seite 31
Gesamtverstärkung Bedingung: MeBgerät: Einstellung Bedingung: MeBgerät: •Aufnahme und Wiedergabe • Röhrenvoltmeter Zeitdauer Stop Oszilloskop • Betriebsart: Normalband Scanning-Puls •Eingangsregler: •Abschwächer •Standard-Eingangspegel: •Oszillograph Mikrofon -72±4 •Widerstand (600Q) Das Gerät auf Stop stellen. •Testband (Leerband) Oszillograph von IC204 an Buchse 31 anschlieBen. (Siehc auch Abbildung NF.Eingang..
Seite 32
(315 Hz a OdB) en la Cinta de ajuste de reproducciån normal, y comprobar que la diferencia entre el nivel del recorrido en avance y del recorrido en retroceso estä RS-B48R ESPANOL dentro de Ios 1,0dB. Después del ajuste, fije los tornillos de ajuste de altura y ångulo de guia de cinta.
Seite 33
Verificaciön de la diferencia de nivel entre el recorrido en avance y en retroceso Respuesta de Condiciön: Equipo: frecuencia 15. Reproducir Ia sefial de ajuste del nivel de reproducciön (315 Hz a OdB) en Ia Cinta de ajuste de reproducciön •...
Seite 34
Efectuar las conexiones tal como se muestra en la Fig. 13. O Circuito Dolby de Medidor Condiciön: Equipo: Poner la UNIDAD en el modo de Cinta normal y cargar la Cinta de prueba (QZZCRA). reducciön de ruido •Modo de grabaciön •...
Seite 35
O Circuito Dolby de Medidor fluorescente CondiciOn: Condiciön: Equipo: Equipo: reducciön de ruido • Modo de grabaciån • Modo grabaciön VTVM •Controles del nivel de • Interruptor Dolby •ATT •Oscilador de AF NR...IN/OUT • Resistor (600Q) entrada...MAX •ATT •Interruptor selector del •Oscilador de AF Dolby NR...B/C...