RF Rx SW868/SW915/SW917/SW922-USB
Telegrammaufbau / Funkempfänger
Telegram structure / Wireless receiver
English
Read configuration
Read the stored configuration of the receiver.
Byte
1
Meaning
PREAMBLE
Response of receiver
Byte
1
Meaning
PREAMBLE
Set the configuration
Byte
1
2
Meaning
PREAMBLE
LEN
Response of receiver
Byte
1
2
Meaning
PREAMBLE LEN
2
3
LEN
CMD
2
3
4
5
LEN
CMD
CONFIG
STATE
3
4
CMD
CONFIG
3
4
CMD
STATE
4
Meaning
PREAMBLE
CHECKSUM
LEN
CMD
CHECKSUM
6
Meaning
PREAMBLE
CHECKSUM
LEN
CMD
CONFIG
STATE
CHECKSUM
Meaning
5
PREAMBLE
CHECKSUM
LEN
CMD
CONFIG
CHECKSUM
Meaning
5
PREAMBLE
CHECKSUM
LEN
CMD
STATE
CHECKSUM
10 / 16
0x03
telegram length (here: 2)
0x6A (read configuration)
check sum for verification of data
(Modulo 256) Byte 1 - 3
0x03
telegram length (here: 4)
0x6A (read configuration)
see: CONFIG Byte
status of the command:
0xAA Successful operation
0xEE Error
check sum for verification of data
(Modulo 256) Byte 1 - 5
0x03
telegram length (here: 3)
0x63 (save configuration)
see: CONFIG Byte
check sum for verification of data
(Modulo 256) Byte 1 - 4
0x03
telegram length (here: 3)
0x63 (save configuration)
status of the command:
0xAA Successful operation,
0xEE Error
check sum for verification of data
(Modulo 256) Byte 1 - 4