ENG | Instruction Manual
START-UP
After having installed the actuator according to its instruction manual, the
power is switched on. Removing the plastic strip from the battery starts
up the room unit.
With SmartComfort 120 the message "E12" will be shown on the display
of the actuator until communication has been established between room
temperature unit and actuator.
TIME AND DATE SETTINGS
Press and hold the edition key
date menu. Each time a value blinks, you can adjust it with the (+) or (-)
keys. Once the desired value is chosen, confirm it by pressing the
The controller will now automatically jump to the next value.
Note: You can at any time return to the previous value by pressing the
escape key
.
Time and day:
Hours
blinking – set hours and press OK.
Minutes
blinking – set minutes and press OK.
Day
blinking – set day and press OK.
Date:
Day number
blinking – set day number and press OK.
Month number
blinking – set month number and press OK.
Year blinking – set year and press OK.
When the message
Save
appears and the green LED blinks, press
confirm the set time and date. Room temperature unit and antenna are
supplied interconnected. The signal strength is checked in Service Mode,
parameter 71.
The room temperature unit is now ready to work.
The operation mode will automatically be comfort temperature mode
if no further settings are made. You can choose a built-in program or
customize your own program.
See chapters Operating Modes and Program Mode P.
Press any key to light up the display. Normally the display shows the
current room temperature. To read the outdoor temperature (provid-
ed that an outdoor sensor is connected) press OK. Press (+) or (-) to
show the set room temperature. As soon as the temperature blinks, it
can be set. The desired temperatures for sleep mode, away mode and
holiday/timer mode are set separately.
The example shows sleep mode early morning day 3
Current stage
of the
program
Current day
Current time
Comfort temperature periods
OPERATING MODES
The unit has three operating modes: Auto, Comfort and Holiday/Timer
mode. Open the cover to have access to the navigation keys
. Select the desired operation mode and press OK.
4
for 2 seconds to open the time and
Selected
program
www.lkarmatur.com
COMFORT MODE
Operating mode with fixed temperature around the clock. To adjust the
comfort temperatur use the (+) or (-) keys. The factory setting is 21 ° C.
Note that the hand symbol is not shown during operation.
AUTOMATIC MODE
In this mode the room temperature unit will follow a chosen built-in
(P1-P9) or customized program (U1 or U2). To set/change a chosen
program, see Program mode P.
You can temporarily override a scheduled temperature change. This is
done by by changing the set temperature value with the (+) or (-) keys.
OK
key.
The newly selected value will blink for some seconds. The symbol
is blinking to show that the current program step has been overridden.
At the next program step the controller will return to the chosen pro-
gram. Note that a change of temperature during a comfort tempera-
ture period will be permanent.
HOLIDAY / TIMER MODE
The holiday/timer mode allows you to set a desired room temperature
for from 1 hour to 255 days. Select program mode
The temperature blinks. Set the temperature and press OK.
Set the duration with the (+) and (-) keys and press OK. The symbol
will blink during the entire period. The display shows the time left until
the end of the period.
When the holiday/timer period has expired the room unit will return
OK
to
to the previous operating mode.
PROGRAM MODE
Open the cover. Use the navigation buttons
program mode P. Press
preset program P1 to P9 or a self-composed user program U1 or
U2 can be selected. Comfort temperature periods are shown in the
program graph at the bottom of the display. A blinking segment
shows the current time.
= Away Mode - Reduced temperature. Factory setting: 17 °C
= Sleep Mode - Reduced temperature. Factory setting: 19 °C
BUILT-IN PROGRAMS P1 TO P9
Program
P1 At work all day Comfort (day 1-5) 06:00 - 09:00,
P2 At work all day,
lunch at home
P3 At home
P4 Day shift
P5 Afternoon shift Comfort 07:00 – 14:00, 21:00 – 24:00
P6 Night shift
P7 Office
P8 Shop
P9 Cottage
The factory temperature settings for away and sleep modes can be changed in the Service
and
menu.
OK
to confirm. With the (+) or (-) buttons a
Comfort / Reduced temperature
16:00 - 23:00,
(day 6-7) 08:00 - 23:00
Comfort (day 1-5) 06:00 – 09:00,
11:00 – 13:00,
16:00 – 23:00, (day 6-7) 08:00 – 23:00
Comfort (day 1-5) 06:00 – 23:00,
(day 6-7) 08:00 - 23:00
Comfort 04:00 – 06:00, 13:00 – 21:00
Comfort 05:00 – 08:00, 15:00 – 22:00
Comfort (day 1-5) 07:00 – 18:00
Comfort (day 1-6) 08:00 – 19:00
Comfort (day 1) 06:00 – 09:00,
(day 5) 15:00 – 24:00, (day 6-7) 06:00 – 23:00
.
01d
blinks.
or
to select