T
he cooker hood is provided with an upper air exit B for discharging fumes externally
for models including chimney flue C ( Suction Version A- exhaust pipe not supplied). If
cooking fumes and vapours cannot be externally discharged, the cooker hood can be
used in the recirculating version F: the installation of 1 active charcoal filter F allows the
recirculation of fumes and vapours through the upper grid G.
M
ake sure that there is a power socket near the hood and that the system has a 30 mA
differential. The mains voltage must be the same as that on the label inside the hood. The
hood has a 1250 mm power cable with or without plug: if it does have a plug, connect
the hood to an accessible approved socket; or if it does not (connection direct to the
mains), fit an approved bipolar switch with a minimum contact opening of no less than
3 mm (accessible). This installation and electrical connection must be executed by a
qualified technician.
P
roduct performance test carried out in accordance with standard (EU) No 65/2014-
Ref: IEC 61591
Maximum performance is achieved by placing the mobile panels, if any, in the open
position.
T
he worktop should be flat and horizontal. The furniture should be cut to measure
before installing the appliance. Remove any chips to avoid compromising the operation
of electrical components. Considering the ventilation of the cooktop, the following must
be provided: -if the cooktop is installed above a drawer, leave a 70 mm space between
the drawer and the top of the cooktop (fig.1).
S
uch tray is designed to contain about 0,7 litre of water; in case of spillage or fall of
fluids on the device, turn off the appliance immediately and empty the tray. If the liquid
fallen on the floor is greater than the maximum capacity of the tray, turn off the device
and contact the customer service immediately. Turn on the suction device only when the
cover is open.To open and close the cover, use only the dedicated slot.