3.Limits on radon concentration
The radon concentration standard varies from region to region (148
Bq/m³ by default), but there are generally some basic standards.
EPA
(USA standards)
WHO standards
EURATOM
(European standards)
The simplest way to reduce indoor radon concentration is to enhance
indoor ventilation. When the radon concentration exceeds 4 pCi/L
(148 Bq/m³), ventilate for at least 10 minutes or more.
Note: 1 pCi/L = 37 Bq/m³.
4.Main features
●Utilizes a semiconductor radon sensor.
●Equipped with a color TFT 2.0 screen and a graphical UI interface for
simpler and more convenient operation.
● Patented radon filtration and radon signal screening technology and an
adaptive integration algorithm.
●With air vents on three sides with high diffusion effect, enabling radon to
quickly diffuse into the device.
●Data is displayed for the first time 6 hours later. The value within the
recent 6 hours is the real-time measurement value of the current
environment. At the same time, it records various viewable data such as
accumulated average, 24h value, 48h value, 72h value, 96h value,
accumulated peak, etc.
●The radon concentration alarm threshold and alpha particle sound can be
set, and the sound switch can be controlled.
≤4pCi/L
(equivalent to 148Bq/m³)
≤100Bq/m³,when >300 Bq/m³, it is
strongly recommended to take
corrective measures.
<300Bq/m³
- 3 -