ANTI-TIP STRAP INSTALLATION TO THE WALL
The UPRIGHT VERTICAL STORAGE rack has been designed to be placed against a wall, on a hard level floor
with the Anti-tip straps firmly anchored into a plasterboard wall with a wooden stud, or a concrete/brick wall.
Please ensure that no equipment is placed on the UPRIGHT VERTICAL STORAGE rack during assembly.
The supplied wall plugs are suitable for concrete and brick walls. For other wall types, special wall plugs
must be used. Wall structures vary. Please consult a construction professional to confirm whether your
wall structure is appropriate for installation of this UPRIGHT VERTICAL STORAGE rack.
The Anti-tip strap 7 should already be attached to the UPRIGHT VERTICAL STORAGE rack. If not, please
follow Step 6 under the rack assembly instructions.
FOR PLASTERBOARD / DRYWALL (for walls with existing studs)
STEP 1 Use a stud finder to locate and mark the location of the stud closest to the position where the
UPRIGHT VERTICAL STORAGE rack will be placed.
STEP 2 The Anti-tip wall bracket should be installed 31.5" (800mm) above the floor height. Mark and drill
7/64" (3mm) pilot holes into the stud at each marked location.
STEP 3 Use three 45mm long screws 11 and fasten the Anti-tip wall brackets firmly into the wall.
STEP 4 Place the UPRIGHT VERTICAL STORAGE rack up against the wall and then tighten the adjustable
strap so it is taut between the wall and the rack. Ensure that all four feet on the Base plate remain on the
ground.
FOR CONCRETE / BRICK WALL
STEP 1 The Anti-tip wall bracket should be installed 31.5" (800mm) above the floor height. Mark and drill
7/32" (5.5mm) holes at each marked location.
STEP 2 Install the supplied wall expansion anchors 12 into the 7/32" (5.5mm) holes until they sit flush with
the wall.
STEP 3 Use three 30mm long screws 11 and fasten the Anti-tip wall brackets firmly into the wall.
STEP 4 Place the UPRIGHT VERTICAL STORAGE rack up against the wall and then tighten the adjustable
straps so they are taut between the wall and the rack. Ensure that all four feet on the base plate remain on the
ground.
Ensure the UPRIGHT VERTICAL STORAGE rack is securely anchored, without any movement before use. We
recommend testing the product by initially placing one weight onto the UPRIGHT VERTICAL STORAGE rack
at a time.