Inhaltsverzeichnis Kapitel 1: PowerEdge R470 System configurations and features............5 Key workloads..................................5 New technologies.................................. 5 Kapitel 2: Product comparison......................7 Kapitel 3: Ansichten und Funktionen des Gehäuses................10 Gehäuse-Ansichten................................10 System configurations - front view for PowerEdge R470 System................. 10 System configurations - rear view for PowerEdge R470 System................14 System configurations - inside view for PowerEdge R470 System................
Seite 4
Rails and cable management information.........................39 Kapitel 11: Betriebssysteme und Virtualisierung................48 Supported operating systems............................48 Kapitel 12: Dell-Systemverwaltung....................49 Integrated Dell Remote Access Controller (iDRAC)....................... 49 Systems Management Software-Supportmatrix......................50 Kapitel 13: Anhang A: Zusätzliche technische Daten................51 Chassis dimensions ................................51 Gewicht des Systems................................. 52 Technische Daten des NIC-Ports............................52...
• Key workloads • New technologies Key workloads The Dell PowerEdge R470 offers powerful performance in a purpose-built, cyber resilient, mainstream server. Ideal for: ● Virtualization/Cloud Scale ● Scale-Out Database ● Edge Compute ● High-Performance Compute ● Software-Defined Storage Node...
Seite 6
Tabelle 1. New technologies (fortgesetzt) Technology Detailed Description Supports RDIMM, DDR5 with ECC up to 6400 MT/s PCIe Gen Gen5 @32 GT/s PCIe Slot Up to two PCIe Slots with x16 lanes in total Flex I/O Rear I/O with: ● 1 x Dedicated BMC Ethernet port ●...
Product comparison Tabelle 2. Comparison of PowerEdge R470 and R660xs Feature PowerEdge R470 PowerEdge R660xs Processor One Intel Xeon 6 processor with up to 144 ● Up to 2 x 4th Gen Intel(R) Xeon(R) cores per processor Scalable Processors (Sapphire Rapids) with up to 32 cores ●...
Seite 8
Tabelle 2. Comparison of PowerEdge R470 and R660xs (fortgesetzt) Feature PowerEdge R470 PowerEdge R660xs Power supply ● 800 W Platinum 100-240 VAC or 240 ● 600 W Platinum 100-240 VAC/ 240 HVDC ● 1500 W Titanium 100-240 VAC or 240 ● 700 W Titanium 200-240 VAC/240 HVDC ●...
Seite 9
Tabelle 2. Comparison of PowerEdge R470 and R660xs (fortgesetzt) Feature PowerEdge R470 PowerEdge R660xs For hot aisle (rear I/O configuration): 816.92 mm (32.16 inches) with bezel 815.14 mm (32.09 inches) without bezel Weight 19.11 kg (42.13pounds) 19.45 Kg (55.33 pounds) Product comparison...
Ansichten und Funktionen des Gehäuses Themen: • Gehäuse-Ansichten Gehäuse-Ansichten System configurations - front view for PowerEdge R470 System Front views of R470 Abbildung 1. Front view of 8 x 2.5 inch -drive system Tabelle 3. The table shows the list of components in front view of the system. Item Ports, panels, and slots Icon...
Seite 11
Abbildung 2. Front view of 8 x EDSFF E3.S -drive system with front I/O Tabelle 4. The table shows the list of components in front view of the system. Item Ports, panels, and slots Icon Description Left control panel Contains the USB port and Mini- Displayport.
Seite 12
Tabelle 5. The table shows the list of components in front view of the system. Item Ports, panels, and slots Icon Description Left control panel Contains the USB port and Mini- Displayport. ANMERKUNG: module is optional, and LCP blank is default in the left control panel.
Seite 13
Abbildung 5. Left Control Panel (LCP)- Secondary panel - KVM module Tabelle 6. Left Control Panel (LCP)- Secondary panel - KVM module Item Indicator, button, or Icon Description connector USB 2.0-compliant port The USB port is 4-pin, 2.0-compliant. This port enables you to connect USB devices to the system.
Tabelle 7. Right Control Panel (RCP) - Primary (fortgesetzt) Item Indicator or button Icon Description Host/iDRAC Direct port The iDRAC Direct port (Type - C USB) enables you to access the iDRAC direct (Type - C USB) Type - C USB features. For more information, see the iDRAC manuals.
Seite 15
Tabelle 9. Rear view of the system with 8 x 2.5-inch drive system (fortgesetzt) Item Ports, panels, or slots Icon Description VGA port Enables you to connect a display device to the system. Abbildung 8. Rear view of the system with 8 x EDSFF E3.S drive system with front I/O Tabelle 10.
Tabelle 11. Rear view of the system with 8 x EDSFF E3.S drive system with rear I/O (fortgesetzt) Item Ports, panels, or slots Icon Description PCIe expansion card riser Blank filler for the PCIe expansion riser slot. blank PCIe expansion card riser Blank filler for the PCIe expansion riser slot.
● Up to 8 x 2.5 inch SAS/SATA/NVMe SSD drives ANMERKUNG: For more information about how to hot swap NVMe PCIe SSD U.2 device, see the Dell Express Flash NVMe PCIe SSD User's Guide at Browse all Products > Data Center Infrastructure > Storage Adapters & Controllers > Dell PowerEdge Express Flash NVMe PCIe SSD >...
Prozessor Themen: • Processor features Processor features The Intel® Xeon® 6 series processor stack is consisted of entirely of efficiency cores (E-Cores) providing ultrahigh core counts optimized for Cloud Service Providers and HPC server applications. Intel® Xeon® 6700E offers improved performance per watt, boosted performance per rack, upgraded memory speeds, enhanced I/O, expanded UPI speeds and added software extension security.
Arbeitsspeichersubsystem Themen: • Supported memory Supported memory Tabelle 13. Memory technology comparison Feature PowerEdge R470 (DDR5) DIMM type RDIMM Transfer speed 6400 MT/s(1DPC) and 5200 MT/s(2DPC) ANMERKUNG: Maximum DIMM transfer speed support dependent on CPU SKU and DIMM population Voltage 1.1 V Tabelle 14.
Externes Speichermedium Storage controllers Dell RAID controller options offer performance improvements, including the fPERC solution. fPERC provides a base RAID HW controller without consuming a PCIe slot by using a small form factor and high-density connector to the base planar.
Tabelle 17. Storage controller feature matrix (fortgesetzt) Model and Interface Cache Write Back RAID Levels Max Drive RAID Form Support Support Connection Memory Cache Support Support Factors Size Gen4 (16 GT/s) NVMe ANMERKUNG: 1. RAID 5/50 removed from entry RAID card. 2.
PowerEdge bietet eine Vielzahl von Optionen, mit denen Informationen zu und von Servern verschoben werden können. Die besten Technologien der Branche werden ausgewählt und diese Adapter werden rigoros geprüft, um eine sorgenfreie, vollständig unterstützte Verwendung in Dell Servern zu gewährleisten. OCP 3.0 Support Supported OCP cards Tabelle 20.
Seite 26
Tabelle 22. PCIe Riser Configurations Config No. Riser configuration No. of Processors PERC type supported Rear storage possible NO RSR Front PERC RF1d (front OCP cage) R2q + R4b Front PERC PCIe-Subsystem...
PowerEdge-Server verfügen über zahlreiche Sensoren, mit deren Hilfe die thermische Aktivität automatisch verfolgt wird. Dies hilft dabei, die Temperatur und somit auch die Servergeräusche und den Energieverbrauch zu reduzieren. Die Tabelle unten enthält eine Liste der Tools und Technologien, die von Dell angeboten werden, um den Stromverbrauch zu reduzieren und die Energieeffizienz zu erhöhen: Themen: •...
Tabelle 24. PSU specifications Clas Heat Frequen AC Voltage DC Voltage Current (A) dissipati cy (Hz) 200—240 V 100—120 V 277 V 240 V - (48— 336 V 60) V (maxim (BTU/hr 800 W Plati 3000 800 W 800 W 9.2—4.5 A 50/60 mixed...
Akustikdesign Acoustical configurations of R470 Dell PowerEdge R470 is a rack server with acoustical output that spans from levels suitable for an office environment to those found in data centers. R470 is designed for use in data centers, some users may prefer to use it in a quieter setting. Please note however in most cases, the idle air mover speed of the system cannot be lowered without changing the configuration of the system, and in some cases, even a configuration change may not reduce idle air mover speeds.
Operating mode: The maximum of the steady state acoustical output at 50% of CPU TDP or active HDDs per C.9.3.2 in ECMA-74 (17 ed., Dec. 2019). Akustische Angaben für PowerEdge Dell kategorisiert Server in der Regel in fünf Kategorien von akustisch akzeptabler Nutzung: ● Kategorie 1: auf Tischplatte in Büroumgebung ● Kategorie 2: auf dem Boden in Büroumgebung ●...
Kategorie 1: auf dem Boden in Büroumgebung Wenn Dell feststellt, dass ein bestimmtes Enterprise-Produkt auf einer Tischplatte in einer Büroumgebung verwendet werden soll, z. B. auf einem Schreibtisch auf Kopfhöhe des sitzenden Benutzers, gelten die akustischen Angaben in der nachfolgenden Tabelle. Beispiele für diese Art von Produkt sind kleine, leichte Tower.
Kategorie 2: auf dem Boden in Büroumgebung Wenn Dell feststellt, dass ein bestimmtes Enterprise-Produkt primär auf dem Boden stehend verwendet werden soll, d. h. sich neben den Füßen des Benutzers befinden wird, gelten die akustischen Angaben der nachfolgenden Tabelle. Der Geräuschpegel des Produkts sollte die Gedanken oder Gespräche des Benutzers, z. B.
Seite 33
Tabelle 29. Dell Enterprise Kategorie 2, akustische Spezifikationen für „auf dem Boden in Büroumgebung“ (fortgesetzt) Messpositionen Kennzahlen Testmodi bezüglich AC0159 (Hinweis: Muss sich in stationärem Zustand befinden, bezüglich bezüglich siehe AC0159, außer wenn unten angegeben) AC0158 AC0159 Stand-by bei 23 Inaktiv bei 23 ±...
Kategorie 3: Verwendung in Gemeinschaftsraum Wenn Dell feststellt, dass ein bestimmtes Enterprise-Produkt vorwiegend an einem allgemeinen Verwendungsort verwendet werden soll, gelten die akustischen Angaben in der nachfolgenden Tabelle. Diese Produkte sind in Laboratorien, Schulen, Restaurants, Büros mit offenem Raumlayout, kleinen belüfteten Schränken usw. zu finden, jedoch nicht in der Nähe einer bestimmten Person und in Mengen, die einige wenige an einem Standort überschreiten.
Seite 35
Kategorie 4: beaufsichtigtes Rechenzentrum Wenn Dell feststellt, dass ein bestimmtes Enterprise-Produkt vorwiegend in einem beaufsichtigten Rechenzentrum verwendet werden soll, gelten die akustischen Angaben in der Tabelle. Die Formulierung „beaufsichtigtes Rechenzentrum“ bezieht sich auf einen Bereich, in dem viele (zwischen zehn und mehreren Tausend) Enterprise-Produkte in der Nähe von Mitarbeitern (d. h. im selben Raum) bereitgestellt werden, die sich (u. U.
Seite 36
Tabelle 31. Dell Enterprise Kategorie 4, akustische Spezifikationen für „beaufsichtigtes Rechenzentrum“ (fortgesetzt) Messpositionen Kennzahlen Testmodi bezüglich AC0159 (Hinweis: Muss sich in stationärem Simulation bezüglich bezüglich Zustand befinden, siehe AC0159, außer wenn unten angegeben) (d. h. AC0158 AC0159 Lüftergeschwin Stand-by bei 23 Inaktiv bei 23 ±...
Kategorie 5: unbeaufsichtigtes Rechenzentrum Wenn Dell feststellt, dass ein bestimmtes Enterprise-Produkt vorwiegend in einem unbeaufsichtigten Rechenzentrum verwendet werden sollte (ohne Blades und Blade-Gehäuse; diese weisen eine eigene Kategorie auf), gelten die akustischen Angaben in der unten stehenden Tabelle. Ein unbeaufsichtigtes Rechenzentrum bezeichnet einen Bereich, in dem viele (dutzende bis tausende) Enterprise-Produkte zusammen bereitgestellt werden, eigene Heiz- und Kühlungssysteme verwendet werden und die Betreiber oder Servicemitarbeiter den...
Seite 38
Tabelle 32. Dell Enterprise Kategorie 5, akustische Spezifikationen für „unbeaufsichtigtes Rechenzentrum“ (fortgesetzt) Messposition Kennzahlen Testmodi bezüglich AC0159 (Hinweis: Muss sich in stationärem Zustand Simulation en bezüglich bezüglich befinden, siehe AC0159, außer wenn unten angegeben) (d. h. AC0158 AC0159 Lüftergeschwin Stand-by bei Inaktiv bei 23 In Betrieb bei Simulation (d. h.
● Supports drop-in installation of the chassis to the rails. ● Support for tool-less installation in 19" EIA-310-E compliant square or unthreaded round hole 4-post racks including all generations of the Dell racks. ● Support for tooled installation in 19" EIA-310-E compliant threaded hole 4-post racks.
Seite 40
● Supports drop-in or stab-in installation of the chassis to the rails. ● Support for tool-less installation in 19" EIA-310-E compliant square, unthreaded round hole racks including all generations of the Dell racks. Also supports tool-less installation in threaded round hole 4-post racks.
Seite 41
Static rails for 4-post and 2-post racks: ● Supports Stab-in installation of the chassis to the rails. ● Support tool-less installation in 19" EIA-310-E compliant square or unthreaded round hole 4-post racks including all generations of Dell racks. ● Support tooled installation in 19" EIA-310-E compliant threaded hole 4-post and 2-post racks.
Abbildung 23. Static rails in 2-post center mount configuration Installation in the Dell Titan-S or Titan-D racks For tool-less installation in Titan or Titan-D racks, the Stab-in/Drop-in sliding rails (B22) must be used. This rail collapses down sufficiently to fit in the rack with mounting flanges that are spaced about 24 inches apart from front to back. The Stab-in/Drop-in sliding rail allows bezels of the servers and storage systems to be aligned when installed in these racks.
Abbildung 25. Rail standoffs seated in J-slots 4. Push the system inward until the lock levers click into place. 5. Pull the blue side release lock tabs forward or backward on both rails and slide the system into the rack until the system is in the rack. Abbildung 26.
Seite 44
Abbildung 27. Pull out the intermediate rail Tabelle 33. Rail component label Number Component Intermediate rail Inner rail 3. Attach the inner rails to the sides of the system by aligning the J-slots on the rail with the standoffs on the system and sliding forward on the system until they lock into place.
Seite 45
Abbildung 29. Install system into the extended rails 5. Pull blue slide release lock tabs forward or backward on both rails, and slide the system into the rack. Abbildung 30. Slide system into the rack Cable management arm (CMA) The optional cable management arm (CMA) organizes and secures the cords and cables exiting the back of the systems. It unfolds to allow the systems to extend out of the rack without having to detach the cables.
Seite 46
Abbildung 31. Sliding rails with CMA Abbildung 32. CMA Cabling Strain Relief Bar (SRB) The optional strain relief bar (SRB) for the PowerEdge R470 organizes and supports cable connections at the rear end of the server to avoid damage from bending. Abbildung 33.
Seite 47
● Tool-less attachment to the rails ● Two depth positions to accommodate various cable loads and rack depths ● Supports cable loads and controls stresses on server connectors ● Cables can be segregated into discrete purpose-specific bundles Rack, Schienen und Kabelführung...
Betriebssysteme und Virtualisierung Themen: • Supported operating systems Supported operating systems The PowerEdge R470 System supports the following operating systems: ● Canonical Ubuntu Server LTS ● RedHat Enterprise Linux ● SUSE Linux Enterprise Server Technische Daten und Details zur Interoperabilität finden Sie unter BS-Support. Betriebssysteme und Virtualisierung...
Dell bietet Verwaltungslösungen, die IT-Administratoren eine effektive Bereitstellung, Aktualisierung, Überwachung und Verwaltung von IT-Beständen ermöglichen. Dell Lösungen und Tools ermöglichen Ihnen eine schnelle Reaktion auf Probleme. Sie unterstützen Sie beim effizienten Management von Dell Servern in physischen, virtuellen, lokalen und Remote-Umgebungen, wobei kein Agent im Betriebssystem installiert werden muss.
● Verfügbar für alle Server. ● Zentrale Systemmanagementfunktionen für kostenbewusste NutzerInnen Eine vollständige Liste der iDRAC-Funktionen nach Lizenz-Tier finden Sie im Benutzerhandbuch für Integrated Dell Remote Access Controller 10 unter Dell.com. Weitere Informationen zu iDRAC10, einschließlich Whitepapers und Videos, finden Sie unter: ●...
Tabelle 36. PowerEdge R470 chassis dimensions (fortgesetzt) Drives Ear to PSU ANMERKU Cold aisle handle Front configuration bezel is not (front I/O) supported in a front configuratio 8 drives 2.5 inch 482.0 mm (19 inches) 434.0 mm (17.1 42.8 mm (1.69 With bezel 750.57 mm 786.141` mm...
If a second PSU is added at run-time, in order for that particular PSU to be enabled, the wattage capacity of the first PSU must equal the second PSU. Otherwise, the PSU is flagged as unmatched in iDRAC and the second PSU is not enabled. Dell PSUs have achieved Platinum and Titanium efficiency levels as shown in the table below. Anhang A: Zusätzliche technische Daten...
91.00% mode Umgebungsbedingungen ANMERKUNG: Weitere Informationen zu Umweltzertifizierungen finden Sie in den Datenblättern zu Produkt und Umwelt in der Dokumentation unter Dell Support. Tabelle 43. Dauerbetriebsspezifikationen für ASHRAE A2 Temperatur Zulässige kontinuierliche Vorgänge Temperaturbereich für Höhen <= 900 m (<= 10 bis 35 °C (50 °F bis 95 °F), wobei die Geräte keiner direkten 2.953 ft)
Tabelle 46. Allgemeine Umgebungsbedingungen für ASHRAE A2, A3 und A4 (fortgesetzt) Temperatur Zulässige kontinuierliche Vorgänge Temperaturgrenzwerte bei Nichtbetrieb -40 bis 65 °C (-40 bis 149 °F) Luftfeuchtigkeitsgrenzwerte bei Nichtbetrieb 5 % bis 95 % relative Luftfeuchtigkeit bei einem Maximaltaupunkt von 27 °C (80.6 °F) Maximale Höhe außerhalb des Betriebs 12.000 m (39.370 Fuß) Maximale Höhe über NN bei Betrieb...
Tabelle 49. Partikelverschmutzung – Technische Daten (fortgesetzt) Partikelverschmutzung Technische Daten ANMERKUNG: Leitfähiger Staub, der den Gerätebetrieb beeinträchtigen kann, kann aus verschiedenen Quellen stammen, einschließlich Fertigungsprozessen und Zinkpartikeln, die sich auf der Beschichtung von Doppelbodenfliesen entwickeln können. ANMERKUNG: Diese Bedingung bezieht sich auf Rechenzentrums- sowie Nicht-Rechenzentrums-Umgebungen.
Seite 57
ANMERKUNG: CPU-TDP bis zu 250 W kann mit erweitertem Kühlkörper und Standardlüfter in einer Konfiguration mit 8 x E3.S- Kaltgang und 8 x 2,5-Zoll-SAS/SATA (NVMe RAID/Direct) unterstützt werden Tabelle 52. Prozessor- und Kühlkörpermatrix Kühlkörper Prozessor-TDP Erweiterter HSK <= 250 W Remote-HSK >...
Anhang B. Einhaltung von Standards Das System entspricht den folgenden Branchenstandards. Tabelle 54. Dokumente zu Branchenstandards Standard URL für Informationen und technische Daten ACPI Advanced Configuration and Power Interface – Technische ACPI Daten, v6.4 Ethernet IEEE Std 802.3-2022 IEEE-Standards MSFT WHQL Microsoft Windows Hardware Quality Labs Windows-Hardwarekompatibilitätsprogramm IPMI Intelligent Platform Management Interface, v2.0 IPMI...
Informationen und Ressourcen für den Server, einschließlich Videos, Referenzmaterial, Service-Tag- Informationen und Kontaktinformationen von Dell. Enterprise Infrastructure Planning Tool Das Online-Tool EIPT von Dell ermöglicht Dell.com/calc (EIPT) einfachere und aussagekräftigere Schätzungen, die Ihnen dabei helfen, die effizienteste Konfiguration zu ermitteln.
Anhang D: Services Themen: • Standardservicelevel • ProDeploy Infrastructure Suite • Ergänzende Bereitstellungsservices • Spezielle Bereitstellungsszenarien • TAG 2: Automatisierungsservices mit Ansible • ProSupport Infrastructure Suite • Specialty Support Services • Beratungsservices • Ressourcen Standardservicelevel ProDeploy Infrastructure Suite Die ProDeploy Infrastructure Suite bietet eine Vielzahl von Bereitstellungsangeboten, um die individuellen Anforderungen eines Kunden zu erfüllen.
● STANDARD-SKUs für die Rackintegration sind nur in den USA verfügbar und erfordern: ○ 20 oder mehr Geräte (Server der R- und C-Serie, VxRail und alle Switches von Dell oder anderen Anbietern) ○ Verwenden Sie informationsbezogene SKUs für Dell Switches oder Produkte von Drittanbietern.
Darüber hinaus wird Basic Deployment in der Regel von großen Unternehmen erworben, die über kompetente technische Mitarbeiter verfügen. Diese Unternehmen benötigen Dell nur, um die Hardware zu installieren, und führen die Softwarekonfiguration selbst durch. Das letzte Anwendungsbeispiel für Basic Deployment ist die Kopplung mit den Factory Configuration Services. Die Server werden werkseitig vorkonfiguriert und der Basic Deployment Service installiert das System im Rack, um die Bereitstellung abzuschließen.
Die Bereitstellung neuer Storage-, Compute- oder Netzwerkgeräte erfordert möglicherweise eine Verbindung zu anderen Servern (auch als Hosts bezeichnet). Das Dell Bereitstellungsteam richtet im Rahmen jedes ProDeploy-Service vier Hosts pro Gerät ein. Wenn der Kunde beispielsweise zwei Speicherarrays kauft, umfasst der ProDeploy-Service automatisch die Konnektivität von jeweils vier Hosts (4 x 2 = 8 Hosts insgesamt pro Projekt, da es zwei Geräte sind).
● Möglichkeit zum Hinzufügen von Bereitstellungsservices zu Netzwerkgeräten von Drittanbietern Bereitstellung von HPC HPC-Implementierungen (High-Performance Computing) erfordern Spezialisten, die erweiterte Funktionssätze verstehen. Dell stellt die weltweit schnellsten Systeme bereit und versteht die Nuancen, die ihre Leistungsfähigkeit ausmachen. HPC-Bereitstellungen werden am häufigsten als kundenspezifische Serviceprojekte ausgeführt. Wir können jedoch kleinere HPC-Cluster unter 300 Nodes mit einer Standard-ProDeploy-SKU durchführen.
Dell Lösungen werden „automatisierungsbereit“ mit integrierten APIs (Application Programming Interfaces) entwickelt, damit Kunden Aktionen für das Produkt programmatisch über Code aufrufen können. Obwohl Dell Anwendungsbeispiele für die Automatisierung mit Ansible veröffentlicht hat, benötigen einige Kunden zusätzliche Unterstützung bei GitOps. Am Ende des Service verfügt der Kunde über die grundlegenden Komponenten, die erforderlich sind, um die Automatisierung zu beschleunigen und zu verstehen, wie die...
Telekommunikationssupport spezialisiert haben. Dieses Add-on bietet auch eine Hardwareverfügbarkeitsgarantie. Das bedeutet, dass Dell bei Ausfall eines Systems bei Problemen mit Schweregrad 1 innerhalb von 4 Stunden dafür sorgt, dass es wieder installiert und betriebsbereit ist. Für Dell werden Vertragsstrafen und Gebühren fällig, wenn SLAs nicht eingehalten werden.
Anwendungstransformation durchgeführt werden können. Wir verwenden präskriptive Ansätze und bewährte Methoden, kombiniert mit dem Portfolio und dem Partnernetzwerk von Dell Technologies, um dabei zu helfen, echte Geschäftsergebnisse zu erzielen. Wir helfen Ihnen bei Ihrer nächsten Transformation, die Multi-Cloud-Umgebungen, Geschäftsanwendungen, DevOps, Ausfallsicherheit für Unternehmen, Modernisierung des Rechenzentrums, Analysen, Zusammenarbeit am Arbeitsplatz und Nutzererlebnisse betreffen könnte.
Ressourcen mithilfe unserer Mitarbeiter und Tools verwaltet. Die zweite ist das „As-a-Service“-Modell oder OPEX-Modell, das wir als APEX bezeichnen. In diesem Service ist Dell für die gesamte Technologie und das gesamte Management dieser Technologie erforderlich. Viele Kunden haben je nach Unternehmenszielen eine Mischung aus den beiden Managementtypen.