● With air vents on three sides with high diffusion effect, enabling radon
gas to quickly diffuse into the device.
● Data is displayed for the first time 6 hours later. The value within the
recent 6 hours is the real-time measurement value of the current
environment. At the same time, it records various viewable data such
as accumulated average, 24h value, 48h value, 72h value, 96h value,
accumulated peak, etc.
● The radon concentration alarm threshold and alpha particle sound
can be set, and the sound switch can be controlled.
● This device provides the function of viewing radon concentration
historical records. The single record can view the data overview of up
to 504 days. One data is saved every 6 hours, and there are up to 10
sets of detection records.
● Automatically starts re-measuring when powered on, and can also be
manually re-measured.
● There is a countdown prompt for the first data update to make it more
intuitive to know when the data will be updated.
● In the screen-off state, it enters a low-power consumption mode.
While having ultra-long battery life, it can still perform normal data
monitoring, data recording and radon concentration alarm.
● Language: Chinese, English.
● The colored progress bar can indicate different color zones according
to the change of radon concentration value.
● Has calendar and clock functions. After shutdown, the clock can
operate normally.
5.Technical specifications
● Sensor: Semiconductor radon sensor
● Measurement range: 3.3Bq/m³ - 37kBq/m³ (0.09 - 1000pCi/L)
- 4 -