Read the text and then Confirm PROCEED
EN
Next: select the Wi fi network you wish to link the pump and the Wi-Fi psw.
Give a name to your pump and confirm with DONE.
IT
BACK UP BATTERY
It is possible to connect to the controller, in the socket on the right, a pack of
batteries (NOT SUPPLIED*) that ensure the pump operation for up to 5 hours
DE
(variable duration depending on the capacity of the batteries). If you decide to
equip XStream SDC with this additional protection system, you need to connect
the battery pack (3 x 3.7 V lithium batteries model 18650) to the appropriate
socket in the controller. During normal operation, the battery pack will be kept
FR
charged by the controller itself and will enter in action when a temporary black out
occurs, guaranteeing controller and pump operation for the estimated time. The
pump, regardless of the programs set, will go to 50% of the power to increase its
autonomy. At the same time, if the alerts have been activated in the CONTRALL
ES
App profile and the connected router is still functioning, the lack of electrical power
will be notified. After a few minutes, the Wi-Fi module will turn off to extend the
batteries life. When the batteries life is about to run out, the pump will shut off to
NL
prevent damage to them. When power is restored, everything will resume as before.
*In SICCE accessory range you can purchase the specific battery box with
a connection cable to plug in the controller. The batteries (3 lithium 3.7 V
model 18650) must be purchased separately from your dealer.
PT
2 years Warranty for Controller, Power adaptor and electronic components.
REGULAR MAINTENANCE
RU
For the periodic maintenance, unplug the pump from the electric outlet/socket and
remove the pump from the tank. Clean the pump and the rotor at regular intervals.
Lime build up or heavy detritus in the water may necessitate more frequent
CN
cleaning. Remove the prefilter grid 8 from the pump 6 with light pressure to the
sides by pulling it down (pic. E1). Rotate the front counterclockwise and remove
the rotor 7 (pic. E2-E3). Carefully clean the pump's components with fresh water
or using a soft brush with soap or vinegar. Rinse all parts well before returning the
pump to the tank. After cleaning, re-assemble all components. SICCE products are
designed for a long life and high, reliable service. Nevertheless, wear over time
can create a little noise even after regular maintenance. Replacements parts are
available.
ADDITIONAL MAINTENANCE
1) Remove the plug from the electrical socket and then completely remove the
pump from the water. 2) Lift the lever slightly (pic. F1) and turn it 90° anticlockwise
(pic. F2). Pull to remove components 3 and 4 (pic. F3) from the back of the pump.
Remove the prefilter grid and the rotor kit (pic. E1-E3), with the aid of a pen,
push from the back towards the front to take out the ceramic bearing 5 (pic. F4).
Pay attention on his positioning to then replace it correctly (pic. F5). 3) Clean the
ceramic bearing 5 with a soft brush to remove any residues or incrustations of salt
or organic material, taking care not to remove it from the rubber. Re-assemble
everything correctly before reconnecting the pump to the electrical socket.
16