852-1813/000-001
7 Configuration
7.1 Default Settings
1. To open the Web Based Management (WBM), launch a Web browser (e. g., Google
Chrome or Mozilla Firefox).
2. Enter the IP address of the product.
3. Click [Enter] to confirm.
Table 6: Default Settings
Setting
IP address
User
Password
7.2 DIP Switches
Table 7: DIP Switches
Nr.
Name
1
PWR
2
RPS
3
Storm
4
QoS
5
P9 100FX
6
P10 100FX ON
En-11
Staus
Beschreibung
ON
The alarm reporting function for the primary power supply
is activated.
OFF
The alarm reporting function for the primary power supply
is deactivated.
ON
The alarm reporting function for the secondary power
supply is activated.
OFF
The alarm reporting function for the secondary power
supply is deactivated.
ON
Storm Control is activated (300 packets per second,
broadcast/DLF).
OFF
Storm control is controlled through software.
ON
Port based QoS on Port 1 ... 2.
OFF
Quality of Service is controlled through software.
ON
100 Mbit/s connection in operation
OFF
1000 Mbit/s connection in operation
100 Mbit/s connection in operation
OFF
1000 Mbit/s connection in operation
En
Default Value
192.168.1.254
admin
wago
s08520000_00000016 V1.0.0 © 2020