Input the dimensions of the engraving file.
Input the required number of lattice points
to be probed as needed. The larger the
probing area, the more lattice points can be
correspondingly increased to ensure probing
accuracy. As the number of probing lattice
points increases, the time required for probing
will also increase.
Input the Z-axis safe height. This value
should not be set too small, otherwise the
tool may easily scrape the material surface
when moving over a slanted surface.
Input the maximum depth of the Z-axis
probing plane. This setting determines the
maximum probing depth. If the downward
probing distance exceeds this value, it will
trigger a machine alarm.
After input and confirming the relevant
parameters, click "Next" to start the automatic
height map lattice probing. The number of
lattice points just set will be displayed here,
and probing will be executed point by point.
The total probing time is related to the set
probing area, the number of lattice points,
and the Z-axis safe height.