Maintenance of the pump and
UVC-unit
Check monthly the operation of the UV lamp via
1
the light indicator on the cover (C-d).
Always disconnect from the mains supply before
2
carrying out any maintenance!
For maintenance of the pump and UVC, first loosen
3
and remove the spray pipe (C-a).
Press the catch (C-h) of the front cover on both
4
sides and lift the cover up.
The pump and the UVC-unit are connected to each
5
other by a 90° bend, loosen one of the swivels (D-i)
to disconnect the pump from the UVC.
Your pump needs regular cleaning. There is no
6
warranty on failures due to dirty pumps and scale
build up inside the pump caused by improper
maintenance.
Depending on usage the rotor of your pump can
7
get worn out and damaged, this is normal, new
rotors can be purchased at your dealer, Combi Clear
2000 Rotor (Art. 06020775), 4000 Rotor (Art.
06020780) 6000 Rotor (Art. 06020775).
The UVC device should be cleaned twice a year. As
8
soon as algae growth increases, check the UVC and
UV-lamp and clean or exchange as needed.
The lamp is hot, wait 10 minutes after switch off
9
before opening the unit.
Slide the red switch lock (E-j) to unlock the unit
10
head and housing.
Turn the unit head counter-clockwise against the
11
stop then carefully pull it out of the housing (E-k).
Loosen the screw (F-l), remove the locknut (F-m).
12
Remove the quartz glass including the gasket by a
slight rotary movement (F-n).
Clean the quartz glass outer face with SuperFish
13
UVC Pump & Clean carefully and check for damage.
Remove the UV-lamp together with UV-tube clip
14
(G-o) and tube protection ring (G-p) and remove
the O-ring (G-q) from the unit head. Clean the unit
head and make sure that it's dry, place a new
O-ring if necessary.
Replace the UV-lamp if necessary (recycling). Insert
15
the (replacement) UV-lamp with a UV-tube clip and
tube protection ring in the fitting of the unit head.
Insert the quartz glass with the gasket in the unit
16
head, slide the locknut over the quartz glass and
tighten it onto the unit head. Place the screw back
and tighten the locknut (H).
Place the unit head with the fitted UV-lamp and
17
quartz glass back into the housing. Turn it
clockwise up to the stop and slide the red switch
lock to the housing (J).
To avoid UVC overheating, switch off the UVC
18
device when no water is flowing past it.
In the winter season, when the system is not used,
19
the Combi Clear filter should be removed to avoid
the risk of freezing.
The UV-lamp should be
replaced yearly.
(Combi Clear 2000: SuperFish UV Clear PL-lamp 5 watt,
G23-105 mm - Art. 06011005)
(Combi Clear 4000: SuperFish UV Clear PL-lamp 7 watt,
G23-105 mm SP - Art. 06011013)
(Combi Clear 6000: SuperFish UV Clear PL-lamp 11 watt,
G23-167 mm SP - Art. 06011017)
GB