KEN002COM
8.1 Mild Exposure: Slight headache, nausea, vomiting, fatigue (often described as
„Flu-like" symptoms).
8.2 Medium Exposure: Severe throbbing headache, drowsiness, fast heart rate.
8.3 Extreme Exposure: Unconsciousness, cardiorespiratory failure, death.
The above levels of exposure relate to healthy adults. Levels differ for those at
high risk. Exposure to high levels of carbon monoxide can be fatal or cause
permanent damage and disabilities. Many cases of reported carbon monoxide
poisoning indicate that while victims are aware they are not well, they become so
disoriented they are unable to save themselves by either exiting the building, or
calling for assistance. Also, young children and household pets may be the first
effected. Familiarization with the effects of each level is important.
WARNING!-Exposure to high levels of carbon monoxide can be fatal or cau-
se permanent damage and disabilities.
Product Specications
Type of Apparatus
Power Supply
Alarm Sound Level
Sensor Type
Sensitivity Setting: Conform with EN
50291-1:2010+A1:2012 standard.
Standby Current:
Alarm Current:
Operation Ambient Condition:
Storage/Transport Ambient Condition:
CO Alarm Silence:
Low Battery Warning Silence:
Product Life
Dimensions
NOTE: This CO alarm is designed to detect carbon monoxide gas from any source of
combustion. It is not designed to detect any other gas.
EN
Type B
DC 3V (1pc sealed-in Lithium-Ion battery
(Type: EVE CR17335))
≥85dB at 100cm @3.2±0.5KHz pulsing
alarm
electrochemical
30PPM Without alarm before 120 minutes
50PPM Between 60 to 90 minutes
100PPM Between 10 to 40 minutes
300PPM Less than 3 minutes
<20µA (average)
<25mA (average)
-10~+40°C, 30~95% non-condensing
-20~+50°C, 10~95% non-condensing
appr. 5 minutes
appr. 9 hours
10 after manufactory date
45 x 75 x 32 mm
11