Incorrect Installation Direction
※ If installing the heater inside a building: ① With the heater placed indoors:
Make holes in the wall for the exhaust pipe to be placed outdoors. Pay
attention to insulating the exhaust pipe as it can become very hot and could
cause a fire. ② With the heater placed outdoors: It's necessary to extend the
exhaust pipe to avoid the exhaust from being sucked into the building from
the back fan position of the heater, which can lead to carbon monoxide
poisoning.
Indoor installation
(wooden floor exhaust pipes need to be protected)
※ Installation position and precautions
①Reserve a 4-inch gap between the air inlet for unobstructed air intake
② Keep the bottom exhaust pipe at a distance of 2 inches from the ground,
and prevent fires if the exhaust pipe temperature is high;
③ Do not bend the exhaust pipe excessively, as it may cause uneven
exhaust flow;
④ The air outlet duct is not easily too long and multiple bends can cause heat
to be unable to be discharged, resulting in a high temperature fault;
⑤ When refueling the fuel tank, do not flow onto the casing, as it will flow
along the inside of the machine to the exhaust pipe position, causing smoke.
Fill the oil level close to the fuel tank port;
⑥Do not block the intake pipe, which will cause insufficient oxygen and the
heater will not work;
Correct Installation Direction
Outdoor installation diagram
- 15 -