4

Setup and Operation

4.3
Setup and Operation
4.3.1

Mounting the Feedline to the Dispenser

Selector Chart Feedline – Tip Adapter
Feedline
1.0x0.3
1.4x0.3
1.7x0.4
2.4x0.4
If the feedline do not fit in the black signed nozzles then the grey signed nozzles can
be used as an alternative (
• As shown in the right graphic,
lift guide lock 10 and release
tube guide 11.
• Put the tube into the groove of the
right tube holder 13.
• Place the tube directly on the rollers.
• Put the tube into the groove of the left
tube holder 13.
• Press the white guide plate of tube
holder on both sides carefully against
tube and fix it with the locking knob.
• Pay attention that the tube is placed directly on the rollers.
The tube is guided and held in place with the tube guide 11.
• Slowly close the tube guide 11 and then turn the rotor manually.
+
Notice!
If the tube guide is tightened without turning the rotor, the shape of the rotor rolls
will be impressed and the tube will not be inserted evenly.
Always turn the rotor after closing the tube guide and press the tube guide 11 against
the rotor.
• Secure the tube guide 11 by following the 1
If a thick tube is inserted and the rotor
stops,
• Lift guide lock 10.
• Unscrew the bigger lock grip from the
smaller one.
• Turn the screw counterclockwise one
revolution.
• Assemble both lock parts.
Tip Adapter
1244446
1109147
1087219
1109318
1001830
1070736
1109317
1070735
1019162
4
)
1.7
2.1
1244447
4
4
4
4
4
4
st
instruction step in reversed order.
2.6
3.5
1244449
1244448
4
4
4
4
4
4
4
4
9