Field of Application (Intended Use)

The Benchtop Peristaltic Dispenser 98548 provides volumetric dispensing of non-
thixotropic materials such as Cyanoacrylates, anaerobics and UV products up to a
viscosity of 5,000 mPas without the need of compressed air. It can be used at manual
and semi-automatic workplaces.
For better dispensing results order the Needle Variety Kit 97262. In the needle kit
dispensing needles with different sizes are included.
1.4

For Your Safety

For safe and successful operation of the unit, read these instructions completely. The
manufacturer cannot be held responsible for damage or injury of any kind because of
misuse or improper application or because of failure to observe safety instructions or
warnings.
Be sure to retain this manual for future reference.
Refer to the technical data sheet of the assigned adhesive under the address
www.loctite-equipment.com
sheet (acc. to the EC Directive 91/155/EC) for the LOCTITE product used at
Henkel AG & Co. KGaA
+49 89 92 68 11 67
089-92 68 11 22
Or
Henkel Corporation
1001 Trout Brook Crossing
Rocky Hill, CT 06067, USA
Follow unconditionally the INSTRUCTIONS of these data sheets!
While under warranty, the unit may be repaired only by an authorized Henkel
service representative.
Warning!
If chemical products are not properly handled, damage to health can result!
Observe general safety regulations for the handling of chemicals!
Observe manufacturer's instructions!
Request a safety data sheet for the LOCTITE
Removing, by-pass or putting out of operation of the safety devices can result in
damage to health and to the unit and is therefore prohibited!
Damage to the power cord or the housing can result in contact with live electrical
parts.
Check the power cord and the unit before each use.
If the power cord or the unit is damaged, do not operate!
Replace a damaged power cord with a new one.
The unit may be opened and repaired only by an authorized service personal.
Do not touch the pump, rolling parts and the rotor's inner parts while the pump is
working.
Check the tube before each use and replace a damaged tube with a new one. Do not
use unspecified tube for the roller.
When inner rotor is stuck with liquids, please send it immediately for repairing.
or request the technical data sheet and the safety data