Setup and Operation
• Close the tube guides 11 as described above and start dispensing.
If product is not dispensed and the rotor stops again repeat steps above with a turn of
½ revolution counterclockwise. Repeat the steps till product is dispensed.
Pay attention that it is possible product is not dispensed and the rotor does not stop
then call the last step off.
4.3.2

Mounting the Feedline to the Applicator

• Pull the tube through the applicator and the applicator tip adapter 17, which
corresponds to the used tube.
• Mount the applicator tip adapter.
• Screw on the sleeve nut to secure the
premounted tip adapter.
• Cut the feedtube as shown is the right
graphic.
• Install the required dispensing needle.
4.3.3

Mounting the Feedline to the Product Bottle

Dispensing Cyanoacrylate:
• Cut the nozzle of the bottle only as
much as it is necessary to insert the
tube.
+
Notice!
It is necessary to minimize moisture
access to the bottle that causes curing of
the CA.
Dispensing Anaerobic:
• Unscrew the dispensing cap.
• Cut the tube in the way described in the right graphic.
• Insert the tube into the bottle.
4.3.4

Setup of the Dispensing Quantity

TIMER MODE:
• Switch button Operation Mode Switch 2 to TIMER.
• With the button
• With the buttons
After a few seconds the adjusted time is set.
10
the digits of the display can be chosen separately.
and
the required dispensing time can be chosen.
CA