6. Troubleshooting
Before starting to correct faults, the electrical power supply must be
disconnected (the plug must be removed from the wall socket).
Fault
The pump does not
operate.
The pump operates
but does not
supplyy water.
The pump stops due
to overheating byy
the automatic safety
device.
kinpumps.com
Cause
1)
No power supply.
2)
The impeller is blocked
1. The liquid level is below the
minimum level.
2. Strainer basket is blocked
3. Drainage hose is blocked
1. TThe power supply is not the same
as that stated on the nameplate.
2. Dirt is blocking the impeller.
3. The pump is pumping too hot water.
4. The pump has run dry.
Solution
1. Measure the voltage and
check that the plug is properly
connected to the socket.
2. Open the strainer basket
and check that the impeller
rotates freely.
1. Turn the pump off.
2. Clean the strainer basket.
3. Remove the hose and clean it.
1-4) Remove the plug from the
socket, find the cause of the
overheating, wait for the pump
to cool down and then plug it in
again.
Primo
GB
9