Failure: The pump furs up regularly after a short
period of time (approx.  to 3 months).
Cause: Excessively high lime additions through
supersaturated salt water, for example, cause
lime deposits on the bearing parts.
Remedy: Reduce the lime additive or submerge
the pump in a 10 l (2.6 USgal.) bucket, half full
with water and 20 ml (.04 pt) of vinegar essence,
and let the pump run for one to two hours. Avoid
splashes. Subsequently, thoroughly rinse in tap
water.
Failure: Hydrofoamer blocks up.
Cause: The drive unit or the impeller are jammed,
caused by wear, snail shell or lime, for example.
Remedy: Remove the foreign body; clean the
pump; replace the drive unit, if and when
necessary. After a delay of 20 minutes the pump
starts operating again automatically.
Disfonctionnement :
régulièrement et en très peu de temps (env.  à 3
mois).
Raison : Trop d'apports calciques dans une eau de mer
saturée en calcium provoquent des précipitations
au niveau des paliers des pompes.
Solution : Réduisez les apports calciques et/ou
placez la pompe dans un seau contenant 10L
d'eau et un verre de vinaigre pur. Après un
fonctionnement de 2 heures, rincez à l'eau
claire. Evitez les éclaboussures !
Disfonctionnement : Blocage de l'Hydrofoamer.
Raison : Entraînement bloqué par l'usure, une coquille
d'escargot ou du calcaire.
Solution : Retirez le corps étranger, si besoin
renouvelez l'entraînement. La pompe redémarre
automatiquement après une temporisation de 20
min.