TROUBLESHOOTING
Problem
Possible cause
Solution
1. No gas supply
1. Check both the
or inadequate gas
gas supply and
pressure.
pressure. 2. Repla-
2. The device valve
ce the valve.
Ignition
is defective.
3. Adjust the
failure
3. The ignition
position of the
electrode has
ignition electrode
come loose and
and make sure it is
has been shifted.
stable.
4. The re detector
4. Adjust the re
has moved or the
detector so that
wire has fallen o.
The ame
the ame turns
5. There is not
goes out
red.
enough oxygen for
immedia-
5. Ensure good
combustion.
tely after
ventilation.
6. The gas
successful
6. Check/change
pressure is too
ignition
the gas supply
low or the amount
or adjust the gas
of gas supplied is
supply valve.
insucient.
In the event of a failure, stop using the device immediately
and contact the manufacturer's service centre. Only a
specialist may repair the device.