5.2 Condensate drain valve adjustment

An automatic condensate drain valve is installed on the rear of the dryer RDX04-18 casing
and on the front of the dryer RDX24-180 casing and can be accessed via a port The condensate
drain valve should be set up so that water can be fully removed from the dryer's heat exchanger.
The condensate drain valve has a TEST button (for checking functionality) and 2 knobs for adjusting
condensate discharge. For forced discharge of condensate, press the TEST button (1) for several
seconds, but no more than 10. Setting frequency of condensate discharge:
1
2
The left regulating knob (2) sets the duration for opening of the valve from 0.5 to 10 seconds.
The right regulating knob (3) sets the frequency for opening the valve from 0.5 to 45 minutes.

5.3 Cleaning condenser

The inner cavities of the dryer and condenser should be cleaned once a week. The condenser
(20) situated on the left inside the dryers RDX04-18, on rear side dryers RDX24-180, should
be cleaned by blowdown with compressed air. The stream of compressed air should be
directed in the opposite direction to the usual air flow and the angle between the air stream
and the plane of the condenser must be approximately 90 degrees.
24
Fig
. 5.2 Drain valve
3
1. TEST button
2. Regulating knob, opening duration
3. Regulating knob, opening frequency
Version 2.7