Inhaltszusammenfassung für Leica Microsystems CM 1100
Seite 1
All manuals and user guides at all-guides.com Service Manual Leica CM 1100 Portable cryostat...
Seite 2
All manuals and user guides at all-guides.com Leica CM 1100 LEICA CM 1100 Service Documentation Service Support Version 1.0 Service Support 04/98 Version 1.0...
Seite 3
All manuals and user guides at all-guides.com Leica CM 1100 LEICA CM 1100 Service Manual Version 1.00 - April 1998 Service Support 04/98 Version 1.0 Page 1 of 1...
Seite 4
All manuals and user guides at all-guides.com Leica CM 1100 Table of contens General Introduction Spare parts information / Safety instructions Revision record Mechanical Part Electronical Part Service Support 04/98 Version 1.0 Page 1 of 1...
Seite 5
All manuals and user guides at all-guides.com Leica CM 1100 Introduction This page provides spare parts information for each module. CAUTION: Ordering Spare Parts: Spare parts can be obtained from your local Leica office or from: TS-Hotline: Fax: Service Support 04/98 Version 1.0...
Seite 6
All manuals and user guides at all-guides.com Leica CM 1100 Introduction Rechtsfragen / Legal questions Copyright Haftung Copyright Liability Service Support 04/98 Version 1.0 Page 2 of 4...
Seite 7
All manuals and user guides at all-guides.com Leica CM 1100 Introduction Question jurdiques / Cuestiones de derecho Copyright Responsabilité Derechos de autor Responsabilidad Service Support 04/98 Version 1.0 Page 3 of 4...
Seite 8
All manuals and user guides at all-guides.com Leica CM 1100 Introduction Sicherheit / Safety / Sécurité / Segurídad Für die Servicetechniker und Servicetechnikerinnen gelten folgende Pflichten: Service technicians have the following obligations: Le personnel technique a les obligations suivantes: ...
Seite 9
All manuals and user guides at all-guides.com Leica CM 1100 Revision record VERSION VERSION NEW PAGES AMENDMENT DETAIL DATE NUMBER Service Support 04/98 Version 1.0 Page 1 of 1...
Seite 10
All manuals and user guides at all-guides.com Leica CM 1100 Table of contents Inhaltsverzeichnis A 1 Übersicht A 1 Overview A 2 Cover A 2 Haube A 3 Bodenwanne A 3 Bottom trough A 4 Handantrieb A 4 Hand drive...
Seite 11
All manuals and user guides at all-guides.com Leica CM 1100 A 1 Overview / Übersicht Fig. / Abb. 230498k1 Service Support 03/99 Version 1.0 Page 1 of 1...
Seite 12
All manuals and user guides at all-guides.com Leica CM 1100 Cover / Haube Fig. / Abb. 120198k1 Service Support 03/99 Version 1.0 Page 1 of 3...
Seite 13
All manuals and user guides at all-guides.com Leica CM 1100 Cover / Haube Disassembly of rear cover (4) Ausbau Haube hinten (4) 1. Remove screws (5) from rear cover (4). 1. Schrauben (5) an der Haube hinten (4) entfernen. 2. Remove nut (9) and washer (8).
Seite 14
All manuals and user guides at all-guides.com Leica CM 1100 Cover / Haube Part Number Qty. Description Remarks Qty.* 0469 31140 Deckel 2101 03205 Screw M4 x 6 DIN 912 Schraube M4 x 6 DIN 912 2171 02114 Washer A4.3...
Seite 15
All manuals and user guides at all-guides.com Leica CM 1100 Bottom trough / Bodenwanne Fig. / Abb. 290498k1 Service Support 03/99 Version 1.0 Page 1 of 3...
Seite 16
All manuals and user guides at all-guides.com Leica CM 1100 Bottom trough / Bodenwanne Part Number Qty. Description Remarks Qty.* 2131 45102 DIN 934 RF Mutter DIN 934 RF 2171 02114 Washer A4.3 DIN 125 RF Scheibe A4,3 DIN 125 RF...
Seite 17
All manuals and user guides at all-guides.com Leica CM 1100 Bottom trough / Bodenwanne Part Number Qty. Description Remarks Qty.* 2101 03111 Screw M4 x 10 DIN 912 RF Schraube M4 x 10 DIN 912 RF 0398 17539 PVC hose...
Seite 18
All manuals and user guides at all-guides.com Leica CM 1100 Hand drive / Handantrieb Fig. / Abb. 220498k1 Service Support 03/99 Version 1.0 Page 1 of 4...
Seite 19
All manuals and user guides at all-guides.com Leica CM 1100 Hand drive / Handantrieb Disassembly of hand drive Demontage Handantrieb 1. Remove screw (1) and washer (2); pull off the 1. Schraube (1) und Scheibe (2) entfernen handwheel (3) and flywheel mass (8).
Seite 20
All manuals and user guides at all-guides.com Leica CM 1100 Hand drive / Handantrieb Part Number Qty. Description Remarks Qty.* 0469 31572 Hand drive assy. Handantrieb, kpl. 2101 03141 Screw Schraube M6 x 10 DIN 912 RF 2171 12110 Washer A6.4...
Seite 21
All manuals and user guides at all-guides.com Leica CM 1100 Hand drive / Handantrieb Part Number Qty. Description Remarks Qty.* 2174 02111 Feather key A4 x 4 x 10 DIN 6885 RF Paßfeder A4 x 4 x 10 DIN 6885 RF...
Seite 22
All manuals and user guides at all-guides.com Leica CM 1100 Coarse feed / Grobtrieb Fig. / Abb. 210498k1 Service Support 03/99 Version 1.0 Page 1 of 3...
Seite 23
All manuals and user guides at all-guides.com Leica CM 1100 Coarse feed / Grobtrieb Disassembly of coarse feed Demontage Grobtrieb 1. Loosen screw (6) and pull out handwheel (5) 1. Schraube (6) öffnen und Handrad (5) sowie and coarse feed shaft (10).
Seite 24
All manuals and user guides at all-guides.com Leica CM 1100 Coarse feed / Grobtrieb Part Number Qty. Description Remarks Qty.* 0469 31840 Coarse feed assy Grobtrieb, kpl. 0111 32419 Packing ring 9 x 22 x7 Dichtring 9 x 22 x7...
All manuals and user guides at all-guides.com Leica CM 1100 Electronic rack / Elektronikeinschub Fig. / Abb. 020997k1 Service Support 03/99 Version 1.0 Page 1 of 4...
Seite 26
All manuals and user guides at all-guides.com Leica CM 1100 Electronic rack / Elektronikeinschub Disassembly of electronic rack (1) Ausbau Elektronikeinschub (1) Disconnect the instrument from the mains Vor Arbeiten an elektrischen Bauteilen before working on electrical components. unbedingt das Gerät vom Netz trennen! 1.
Seite 27
All manuals and user guides at all-guides.com Leica CM 1100 Electronic rack / Elektronikeinschub Disassembly of radio interference Demontage Funkentstörfilter (2) suppression capacitor (2) 1. Elektronikeinschub (1) ausbauen. 1. Disassemble electronic rack (1). 2. Sämtliche Kabelverbindungen zum Funkentstörfilter (2) trennen.
Seite 28
A8:4 DIN 125 RF Scheibe A8,4 DIN 125 RF 0469 31642 Rectifier board Gleichrichterplatine 0469 31641 Loom of cables CM 1100 Kabelsatz CM1100 2101 43127 Screw M4 x 8 DIN 7985 RF Schraube M4 x 8 DIN 7985 RF 2101 43119...
Seite 29
All manuals and user guides at all-guides.com Leica CM 1100 Compressor / Verdichter Fig. / Abb. 280498k1 Service Support 03/99 Version 1.0 Page 1 of 3...
Seite 30
All manuals and user guides at all-guides.com Leica CM 1100 Verdichter Part Number Qty. Description Remarks Qty.* 0469 31800 Suction pressure pipe WT Saugdruckleitung WT 0469 32154 Rubber feet, reinforced for 120V/230V units Gummifüße, verstärkt für 120V/230V Geräte 0469 32715 Startup capacitor, 160V/150µF...
Seite 31
All manuals and user guides at all-guides.com Leica CM 1100 Verdichter Part Number Qty. Description Remarks Qty.* 0435 30733 Startup relay 1351031 for 120V units Compressor FF 7.5 HBK Anlaufrelais 1351031, für 120V Geräte, Kompressor FF 7,5 HBK 0435 31966...
Seite 32
All manuals and user guides at all-guides.com Leica CM 1100 Microtome / Mikrotom Fig. / Abb. 220798k1 Service Support 03/99 Version 1.0 Page 1 of 4...
Seite 33
All manuals and user guides at all-guides.com Leica CM 1100 Microtome / Mikrotom Disassembly of microtome and Ausbau Mikrotom mit Montageplatte mounting plate 1. Deckel (15) abnehmen. 1. Take off lid (15). 2. Aufblockstation, kpl. (20) nach vorne durch die Gehäuseöffnung herausnehmen.
Seite 34
All manuals and user guides at all-guides.com Leica CM 1100 Microtome / Mikrotom Part Number Qty. Description Remarks Qty.* 0504 31117 Slot protection bellow Faltenbelag 0504 31116 Microtome housing Gehäuse Mikrotom 0504 31269 Knob with engraving Knopf mit Gravur 2101 43131...
Seite 35
All manuals and user guides at all-guides.com Leica CM 1100 Microtome / Mikrotom Part Number Qty. Description Remarks Qty.* 0469 31429 Handwheel with handle Handrad mit Umlenkgriff 0469 31782 Freezing stage assy. Aufblockstation, kpl. 0469 31781 Freezing stage Aufblockstation 0401 13487...
Seite 36
All manuals and user guides at all-guides.com Leica CM 1100 Anti-roll guide / Schnittstrecker Fig. / Abb. 070598k2 Service Support 03/99 Version 1.0 Page 1 of 3...
Seite 37
All manuals and user guides at all-guides.com Leica CM 1100 Anti-roll guide / Schnittstrecker Disassembly of anti-roll guide Demontage Schnittstrecker 1. Remove grip (10) and pull out anti-roll plate 1. Griff (10) entfernen und Antirollplatte (19) (19) upwards. nach oben herausziehen.
Seite 38
All manuals and user guides at all-guides.com Leica CM 1100 Anti-roll guide / Schnittstrecker Part Number Qty. Description Remarks Qty.* 0504 31957 Anti-roll guide assy. Schnittstecker, kpl. 2101 12111 Screw M4 x 20 DIN 6912 VZ Schraube M4 x 20...
Seite 39
All manuals and user guides at all-guides.com Leica CM 1100 A 10 Knife holder / Messerhalter Fig. / Abb. 130598k1 Service Support 03/99 Version 1.0 Page 1 of 4...
Seite 40
All manuals and user guides at all-guides.com Leica CM 1100 A 10 Knife holder / Messerhalter Disassembly of knife holder CE assy. Demontage Messerhalter CE kpl. Schmalband und Breitband low and high profile version 1. Turn clamping lever (13) and pull out to the 1.
Seite 41
All manuals and user guides at all-guides.com Leica CM 1100 A 10 Knife holder / Messerhalter Pressure plate and clearance angle Justage Andruckplatte und Freiwinkel adjustment 1. Andruckplatte (10) in Position bringen und Schrauben (11) leicht anlegen. 1. Bring pressure plate (10) in correct position and lightly tighten screws (11).
Seite 42
All manuals and user guides at all-guides.com Leica CM 1100 A 10 Knife holder / Messerhalter Part Number Qty. Description Remarks Qty.* 0504 31947 Knife holder CE, high profile Messerhalter CE Breitband, kpl. 0504 31804 Knife holder CE, low profile Messerhalter CE Schmalband, kpl.
All manuals and user guides at all-guides.com Leica CM 1100 Table of contents Inhaltsverzeichnis B 1 Safety instructions B 1 Sicherheitsvorschriften B 2 Technical data B 2 Technische Daten B 3 First use of the instrument B 3 Erstinbetriebnahme B 4 Wiring diagram...
All manuals and user guides at all-guides.com Leica CM 1100 Safety instructions / Sicherheitsvorschriften Transport und Aufstellung Transport and installation • • Das Gerät darf nur waagerecht oder leicht The instrument must be transported in an upright position only, or at an angle of max.
Seite 45
All manuals and user guides at all-guides.com Leica CM 1100 Safety instructions / Sicherheitsvorschriften • • Caution: Achtung bei 240 V Netzspannung! 240 V units may be operated only with the Diese Geräte dürfen nur mit dem mitgeliefer- step-up transformer supplied with the in-...
Seite 46
All manuals and user guides at all-guides.com Leica CM 1100 Safety instructions / Sicherheitsvorschriften Removal of the microtome Ausbau des Mikrotoms • • Before removing the microtome, turn the Vor Ausbau des Mikrotoms Gerät ausschal- instrument off with the mains switch! ten! •...
All manuals and user guides at all-guides.com Leica CM 1100 Technical data Operating temperature range: 18 °C to 35 °C All specifications related to temperature are valid only for an ambient temperature up to 22 °C and for an air humidity lower than 60%!
All manuals and user guides at all-guides.com Leica CM 1100 Technische Daten Betriebstemperaturbereich: 18 °C bis 35 °C Sämtliche Temperaturangaben beziehen sich auf eine Umgebungstemperatur von 22 °C und Luftfeuchtigkeit von max. 60%! CM 1100-1 CM 1100-3 CM 1100-11 Nennspannung 230 V AC ±10%...
All manuals and user guides at all-guides.com Leica CM 1100 First use of the instrument / Erstinbetriebnahme Einschalten des Gerätes Switching on After transporting, wait at least 4 hours before Bei der Erstinbetriebnahme darf das Gerät erst turning the instrument on. This waiting period...
Seite 50
All manuals and user guides at all-guides.com Leica CM 1100 B 3 First use of the instrument / Erstinbetriebnahme Functions of the control unit Funktionen des Reglers Der Regler besteht aus einem 3stelligen Display für The control unit has a 3-digit display for actual and...
Seite 51
All manuals and user guides at all-guides.com Leica CM 1100 First use of the instrument / Erstinbetriebnahme Einstellen der Parameter Setting user definable parameters • • Zum Aufrufen des Parameterprogrammierung To access parameter programming, press the die ‘P‘-Taste drücken. P-button.
Seite 52
All manuals and user guides at all-guides.com Leica CM 1100 First use of the instrument / Erstinbetriebnahme Starting and terminating a manual defrost Starten und Beenden der manuellen Bedarfs- cycle abtauung • • To activate manual defrosting, press 'P' and the Zum Aktivieren der manuellen Bedarfsab- 'Arrow-up' key simultaneously.
Seite 53
All manuals and user guides at all-guides.com Leica CM 1100 First use of the instrument Temperature selection chart (in minus °C) Tissue 10 - 15 15 - 25 25 - 30 Adrenals Bone marrow Brain Bladder Breast- fatty Breast - little fat...
All manuals and user guides at all-guides.com Leica CM 1100 Erstinbetriebnahme Temperaturtabelle (in minus °C) Gewebetyp 10 - 15 15 - 25 25 - 30 Nebenniere Knochenmark Hirn Blase Brustgewebe, fettreich Brustgewebe mit weniger Fett Knorpel Gebärmutterhals Fettgewebe Herz und Gefäße...
All manuals and user guides at all-guides.com Leica CM 1100 Wiring diagram / Schaltplan Abb. 290798k2 Service Support 03/99 Version 1.0 Page 1 of 2...
Seite 56
All manuals and user guides at all-guides.com Leica CM 1100 Wiring diagram / Schaltplan Abb. 290798k1 Service Support 03/99 Version 1.0 Page 2 of 2...
All manuals and user guides at all-guides.com Leica CM 1100 Layout of cables / Kabelverlegung Abb. 131097en Service Support 03/99 Version 1.0 Page 1 of 2...
Seite 58
All manuals and user guides at all-guides.com Leica CM 1100 Layout of cables / Kabelverlegung Abb. 131097k1 Service Support 03/99 Version 1.0 Page 2 of 2...
All manuals and user guides at all-guides.com Leica CM 1100 Cable connections / Kabelanschluß B 6.1 Terminal strip JX2 / Anschlußleiste JX2 Abb. 290798k4 Service Support 03/99 Version 1.0 Page 1 of 5...
Seite 60
All manuals and user guides at all-guides.com Leica CM 1100 Cable connections / Kabelanschluß B 6.2 Terminal strip JX1 / Anschlußleiste JX1 Abb. 290798k5 Service Support 03/99 Version 1.0 Page 2 of 5...
Seite 61
All manuals and user guides at all-guides.com Leica CM 1100 Cable connections / Kabelanschluß B 6.3 Compressor / Verdichter Abb. 280798k1 Page 3 of 5 Service Support 03/99 Version 1.0...
All manuals and user guides at all-guides.com Leica CM 1100 Cable connections / Kabelanschluß B 6.4 Rack / Einschub Abb. 290798k3 Service Support 03/99 Version 1.0 Page 4 of 5...
All manuals and user guides at all-guides.com Leica CM 1100 Cable connections / Kabelanschluß B 6.5 Electronic rack / Elektronikeinschub Refrigeration control unit / Regler Solenoid valve coil / Magnetventil-Spule Terminal strip JX3 / Anschlußleiste JX3 Fan / Ventilator Heater 1 / Heizung 1...
Seite 64
All manuals and user guides at all-guides.com Leica CM 1100 Control unit, parameters and settings Programming for service personnel: After pressing five times P it is possible to enter the code. The input code is 88. The following table shows the number of the parameters, their settings and the default values.
Seite 65
All manuals and user guides at all-guides.com Leica CM 1100 Procedural Instructions Abb. 120299k1 Page 1 of 3 Service Support 03/99 Version 1.0...
Seite 66
All manuals and user guides at all-guides.com Leica CM 1100 Procedural Instructions Abb. A8-1 Service Support 03/99 Version 1.0 Page 2 of 3...
Seite 67
All manuals and user guides at all-guides.com Leica CM 1100 Procedural Instructions Abb. A8-2 Service Support 03/99 Version 1.0 Page 3 of 3...
Seite 68
All manuals and user guides at all-guides.com Short Information Acrobat Reader / Kurzinformation Acrobat Reader Last page Letzte Seite Next page Nächste Seite Previous page Vorherige Seite First page Erste Seite Show / hide navigation window Navigationsfenster anzeigen / ausblenden Print Drucken Save...