Mount the bracket in the wall in upright position above the water
container (which contains a solution of pH reducing acid and
water).
Place the pump in vertical position (with the tubes below) on the
wall, above and centered with the "Mounting bracket". Then go
down the pump until it is joined with the bracket.
Connect the pump to the MC122 pH controller (on the black and
white outlet). The pump will discharge 0,08 cL every 2 seconds.
Place the plug and B/W outlet far away from water!
Before servicing (maintenance) on the pump (e.g. changing
tube), please disconnect the equipment.
It is suggested to dissolve 10 cL of pH reducing acid in a 5L container of mineral water.
Depending on the volume of your tank and the brand of your pH reducing acid (if it is
more or less concentrated), this quantity will be balanced. It is better to dissolve more
than less. It is suggested to use an airstone on the bottom of your tank. The pump can
be attached directly to the container of the solution.
OPTIONAL ACCESSORIES:
M10004B
pH 4.01 buffer solution, 20 ml sachet (25 pcs)
M10007B
pH 7.01 buffer solution, 20 ml sachet (25 pcs)
M10010B
pH 10.01 buffer solution, 20 ml sachet (25 pcs)
M10000B
Electrode rinse solution, 20 ml sachet (25 pcs)
MA9015
Electrode storage solution, 20 ml sachet (25 pcs)
WARRANTY:
These instruments are warranted from all defects in materials and manufacturing for a period of two years
from the date of purchase. The electrode is warranted for a period of 6 months.
If during this period, the repair or replacement of parts is required, where the damage is not due to negli-
gence or erroneous operation by the user, please return the parts to either dealer or our office and the repair
will be effected free of charge.
Note: We reserve the right to modify the design, construction and appearance of our products without ad-
vance notice.
www.milwaukeeinstruments.eu
USER MANUAL
MILWAUKEE MC122 PH CONTROLLER
WITH MP810 1,5 L/H DOSING PUMP
SPECIFICATIONS
MC122 pH Meter
Range
0.0 to 14.0 pH
Resolution
0.1 pH
±0.2 pH (@25°C)
Accuracy
Setpoint
5.5 to 9.5 pH
Alarm / Output
active when measure is
Power Socket
higher/lower than selected
setpoint depending on
user selection
Power drivers
115VAC, 2A, 60Hz
or 230VAC, 1A, 50Hz
pH electrode
MA911B/2 (included)
0 to 50°C, 95% RH
Environment
not condensing
Power supply
12 VDC (included)
Dimensions
148.5 x 82.5 x 32 mm
Weight
180 g
MC720
MP810 Peristaltic Dosing Pump
• Constant Dosing flow of 1,5 l/h
(25 cc/min)
• No regulation
• Maximum pressure: 1 bar
• Made of Polipropilene (PP)
• Peristaltic tube in Santoprene
• Power supply: 230 VAC ± 10%
Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Milwaukee MC720

  • Seite 19: Installation Des Steuergeräts

    GERMAN BENUTZERHANDBUCH - MC720 MILWAUKEE MC122 PH-REGLER SPEZIFIKATIONEN MC122 pH-Messgerät BEREICH 0,0 bis 14,0 pH AUFLÖSUNG 0,1 pH ±0,2 pH (@25°C) EINSTELLWERT 5,5 bis 9,5 pH ALARM/AUSGANGSSTROMBUCHSE aktiv, wenn der Messwert je nach Benutzerauswahl höher/niedriger als der ausgewählte Sollwert ist...
  • Seite 20: Optionales Zubehör

    Verbinden Sie den weichen Schlauch mit der Pumpe (Impuls – Pfeil nach unten). Die Injektionsarmatur wird nur am Ende dieses Schlauchs angebracht, um in eine Rohrleitung zu injizieren. (Diese Armatur hat ein Gewinde, das sie mit der Rohrleitung verbindet.) Montieren Sie die Halterung in aufrechter Position über dem Wasserbehälter (der eine Lösung aus pH-senkender Säure und Wasser enthält) an der Wand. Platzieren Sie die Pumpe in vertikaler Position (mit den Schläuchen unten) an der Wand, über und zentriert mit der „Montagehalterung“.