TROUBLESHOOTING
DANGER
Risk of electric shook. Turn off the appliance and remove the main
plug prior to performing any care and maintenance work. Repair work
and work on the electrical components may not only be performed by
an authorized customer service. You can rectify minor faults yourself
with the help of the following overview. If in doubt, please consult the
authorized customer service.
Symptom
Machine refuses
to start
Fluctuating pressure
Machine stops
|
34
Multi-Functional High Pressure Washer (4in1) 130bar
Cause
Machine not plugged
in
Defective socket
Fuse has blown
Defective extension
cord
Pump sucking air
Valves dirty, worn out
or stuck
Pump seals worn out
Incorrect mains
voltage
Thermal sensor
activated Nozzle par-
tially blocked
Recommended action
Plug in machine
Try another socket.
Replace fuse. Switch off other
machines.
Try without the extension cord.
Check that hoses and connections
are airtight.
Clean and replace or refer to local
distributor
Clean and replace or refer to local
distributor
Check that the mains voltage
corresponds to specification on the
model tag.
Leave the washer for 5 minutes to
cool down. Clean the nozzle