3. Please proceed according to the following LED status
messages:
Status
Meaning
"Correct" LED
Vehicle battery
"Correct" LED
is OK and can be
lights up green
started.
The state of char-
"Correct" LED
ge of the vehicle
flashes green
battery is very low.
Terminals are
Red LED lights up
connected with
reversed polarity.
Note: If all existing connections are OK and no LED lights up, the
cause is probably a faulty vehicle battery. Replace the faulty
vehicle battery as soon as possible.
4. As soon as the engine is running, remove the terminals from the
battery. Note: first remove the black terminal and then the red
terminal.
5. Leave the engine running as the alternator recharges the
installed vehicle battery. At very low temperatures, it may be
necessary to make several attempts to start the engine.
The waiting time between two start attempts should be at least
one minute. The maximum number of possible jump-start
attempts should not exceed 4 within 10 minutes.
If too many start attempts have been made in succession, the
'Correct' LED will alternate between red and green and no further
start attempts can be made. After waiting for 10 minutes, the
jump-start function is available again, provided there is still
sufficient battery capacity and the integrated safety device allows
it.
‫ ׉‬OUTPUTS AND FUNCTIONS
2x USB-A output 5 V/2.4 A – 3.0 A | 1x USB type C output 5 V/3
A: Connect the end device to be charged to the ANSMANN jump
starter using the USB cable provided. Then press the on/off switch
and the charging process begins.
Output hollow plug socket 15 V/10 A: Connect the end device to
be charged to the jump starter using a suitable lead. Then press
the on/off switch and the charging process begins.
1x USB type C input 5 V/3 A: Connect the ANSMANN jump starter to
a USB power adapter with the supplied USB cable and the charging
process starts automatically.
Jump leads adapter: The jump leads included in the scope of
delivery are connected via the jump leads connection..
Rechargeable battery capacity indicator::
• 100% capacity = 4 LEDs light up
• 75% capacity = 3 LEDs light up
• 50% capacity = 2 LEDs light up
• 25% capacity = 1 LED lights up
14
Application
If additional starting support
is required, press the 'Boost'
button twice in succession
with a time delay of at least 1
second.
The vehicle can be started
within 30 seconds.
Press the 'Boost' button 1×,
The vehicle can be started
within 30 seconds.
Connect the terminals with
the correct polarity.
Torch function: Press and hold the on/off switch for 3 seconds to
switch on the LED. Press again to switch on the strobe light and
press again to switch on the SOS function.
TECHNICAL DATA
Battery:
LiPo 16000 mAh/59,2 Wh
Input:
USB-C:
Output:
USB-C1 5.0 V/3.0 A/15.0 W
USB-A1: 5.0 V/3.0 A/15.0 W
USB-A2 5.0 V/2.4 A/12.0 W
Output 1: 15.0 V/10.0 A/150.0 W
12 V jump starter: 600 A (2500 A max.)
TROUBLESHOOTING
Problem
Possible cause
Jump starter
Voltage of jump starter
does not
too low
switch on
• Voltage of jump starter
too low
Jump starter
• Negative and positive
does not
poles reversed
work
• Temperature
the specified
rature range
• Overload protection
All LEDs are
• Appliance too warm/cold
flashing
• Ambient temperature too
high/low
‫ ׉‬ENVIRONMENTAL INFORMATION | DISPOSAL
Dispose of packaging after sorting by material type. Cardboard and
cardboard to the waste paper, film to the recycling collection.
Dispose of the unusable product in accordance with legal
provisions. The "waste bin" symbol indicates that, in the EU, it is
not permitted to dispose of electrical equipment in household
waste.
For disposal, pass the product on to a specialist disposal point for
old equipment, use the return and collection systems in your area
or contact the dealer from whom you purchased the product.
Batteries and rechargeable batteries contained in
electrical appliances must be disposed of separately whenever
possible.
Always dispose of used batteries & rechargeable batteries (only
when discharged) in accordance with the local regulations and
requirements.
Improper disposal may result in toxic ingredients being released
into the environment, which may have adverse health effects on
5V DC/3 A/15 W
9.0 V/2.0 A/18.0 W
12.0 V/1.5 A/18.0 W
Solution
Charge the battery/jump
starter
• Charge the battery/jump
starter
• Connect terminals
correctly
outside
• Attempt to restart
tempe-
within the appro- priate
temperature range
• Switch off appliance and
check
• Maintain temperature
from +5C° to +40C°
• Maintain ambient
temperature from -15 C°
to +40C°