5
Before taking any troubleshooting action, disconnect the pump from
the power supply (i.e. remove the plug from the socket).
If there is any damage to the power cable or pump, any necessary
repairs or replacements must be performed by the manufacturer or
his authorized customer support service, or by an equally -qualified
party, in order to prevent all risks.
The pump
won't start
The pump won't stop 1. Float malfunction, clean or replace
The pump works, but
the supply is
insufficient or nil
kinpumps.com
1.
There is no electric power.
2.
The ON/OFF switch is OFF
3.
The impeller is blocked
float
2. The pump cannot empty the tank to
stop level
1. The drain line is blocked, any non-
return valves are partially closed.
2. There is an air bubble under the pump
BKL Series
Solutions
1. Check that there is voltage
in the socket and that the plug
is properly inserted
2. Set switch to ON
3. Check that the impeller can
rotate freely
1. Clean or replace the float
2. Check whether there is a
leak in the system
- No non-return valve is fitted
to prevent the liquid from
flowing back
- The pump must be replaced
with one with a larger capacity
1. Check drain line
2. Remove air bubble
GB
9