Number of auxiliary contacts
Number of safety contacts
Safety classification
Standards
Performance Level, up to
Category
B
Normally-closed contact (NC)
10D
Note
B
Normally-open contact (NO)
10D
Note
Mission time
Safety classification - Fault exclusion
Please note:
Performance Level, up to
Category
Note
Mission time
Safety classification - Guard locking function
Performance Level, up to
Note (Performance Level)
Mechanical data
Mechanical life, minimum
Actuating play in direction of actuation
Holding force F
in accordance with EN ISO 14119
Zh
Holding force F
, maximum
max
Latching force
2
4
EN ISO 13849-1
c
1
2,000,000 Operations
Electrical life on request.
1,000,000 Operations
at 10% I
and ohmic load
e
20 Year(s)
Can be used when fault exclusion for dangerous damage to the 1-
channel mechanism is permissible and sufficient protection against
manipulation is guaranteed.
d
3
for 2-channel use and with suitable logic unit.
20 Year(s)
e
Information for the safety classification of the guard locking function
is documented in the "Operating instructions" or in the "Operation
and mounting" instructions.
1,000,000 Operations
5.5 mm
2,000 N
2,600 N
30 N
5-19