the instructions in the care section.
- Always store the pressure cleaner, parts, and accessories in a place that
is inaccessible to children. The ideal storage temperature is between
10 °C and 30 °C. Store the power washer indoors to prevent the water
in the unit from expanding under freezing conditions.
FROST PROTECTION
ATTENTION!
Appliances and accessories that are not completely drained can be
destroyed by frost.Completely drain Appliances and accessories and
protect them against frost. To avoid damage:
- Detach the appliance from the water supply.
- Detach the spray lance from the trigger gun.
- Turn on the appliance "ON/OFF".
- Push the lever of the trigger gun until no more water is escaping.
- Release the lever of the trigger gun.
- Lock the lever of the trigger gun.
- Turn off the appliance "ON/OFF".
- Store the appliance and the entire accessories in a frost-free room.
CARE AND MAINTENANCE
CHANGE OIL IN THE PUMP
Lubricant oil should be changed in the first 50 hours of operation, and
then oil change should be taken in every 100 hours.
- Loose oil drainage plug.
- Tilt the opposite side of oil drainage higher, making the oil drainage
facing the oil drain pan straightly.
- Remove the oil drain plug, and drain the waste oil.
- After draining the oil completely, put the oil drainage plug back.
- Tighten the oil drain plug and fill in new oil (SAE 5W-40) till the oil level
indicator window is half.
- covered by the new oil.
- Put back the oil cap and tighten it.
30
Induction high Pressure Washer