Setting the temperature control
Key Function
- Unlock key: Press and hold for two seconds to unlock.
- Light/CF key: Short press to toggle the light on/off. Hold the button to switch between
Fahrenheit and Celsius.
- Add key: Raise the temperature.
- Minus key: Lower the temperature.
Automatic locking function
- Key locks automatically after 20 seconds of inactivity. Plus and minus buttons are
disabled when locked. Light/CF button and unlock button remain functional.
Auto light off function
Light turns off automatically after 10 minutes of inactivity.
Adjust able temperature range
5°C (41°F) to 18°C (64°F)
Temperature display range
0-37°C (32-99°F)
Display
Celsius: Displays set temperature when actual temperature is within ±1°C.
Fahrenheit: Displays set temperature when actual temperature is within ±2°F.
Error code
LL: When the temperature is below 0°C, 'LL' flashes and the appliance stops cooling.
If the temperature probe is short-circuited or disconnected, the set temperature value is
displayed.
If the measured temperature exceeds 37°C, the set temperature value is displayed. The
compressor will work for 15 minutes, then stop for 18 minutes.
Forced defrosting function
- Compressor stops for 40 minutes after every 12 hours of operation.
Memory function
- Control board remembers temperature settings and Fahrenheit/Celsius state after
power-off.
OPERATING YOUR UNIT
4