Parker Hiross Hyperchill Plus ICEP040 Benutzerhandbuch Seite 15

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4.4.2
Temperature control
PARAMETER
CODE
SEt
Temperature control set point
Temperature control set point
SEt
" CPt= On"
Temperature control differential
(NOT visible with code " CPt=
dIFI
On")
4.4.3
Energy saving temperature control
PARAMETER
CODE
ESE
energy saving enable
SEt_ES
Set energy saving
4.4.4
Compressor parameters
PARAMETER
CODE
dAS
Minimum `On' time.
Minimum time between two com-
dES
pressor switch-ons.
AbCI
Compressor hour counter 1
4.4.5
B1, B2, B3 sensor parameters
PARAMETER
CODE
HA1
High temperature alarm (water)
LA1
Low temperature alarm (water)
High temperature alarm (eva-
HA2
porator)
Low temperature alarm (eva-
LA2
porator)
High temperature alarm (am-
HA3
bient)
Low temperature alarm (am-
LA3
bient)
4.4.6
Differential dinamic temperature parameter
PARAMETER
CODE
Parameter
Differential
Water minimum set
Water maximum set
English
4.5 Change parameters
Parameter (SEt / dIFI/ dEF )
4.5.1
TYPE
DEFAULT
Fig.2
--
D
esc
set
20.0
D
4.0
D
PAr
set
TYPE
DEFAULT
OFF
D
P_nA
20
D
TYPE
DEFAULT
2
F
F
5
set
0
D
TYPE
DEFAULT
60
D
-20
U
60
U
CF30
3
U
4.5.2
Water temperature setting (see fi g.1/2)
60
U
1. Turn the main swicth (QS) to "ON" and wait for the "OFF" visualiza-
tion.
-20
U
2. Press the buttons "
type "D" .
3. Select the parameter "PAr"using "
TYPE
DEFAULT
OFF
U
press the button "
5
4. Select the parameter "tEr"using "
U
10
U
press the button "
25
5. Select the parameter "SEt"using "
U
press the button "
6. Change the value using "
set
button "
" to confi rm and exit.
tEr
CnP
PbI
r9E
set
set
set
HA1
Ar9
set
C1H2
C1H
diFI
SEt
CF31
CF32
dEF
esc
set
" "
" together to enter on the parameter
"and "
" buttons and
set
" to enter.
"and "
" buttons and
set
" to enter.
"and "
" buttons and
set
" to enter.
"and "
" buttons and press the
ICEP040-060
esc
7. Press the button "
" three times to exit.
4.5.3
Differential setting (see fi g.1/2)
1.Turn the main swicth (QS) to "ON" and wait for the "OFF" visualiza-
tion.
esc
set
2.Press the buttons "
" "
" together to enter on the parameter
type "D"
3.Select the parameter "PAr"using "
"and "
set
press the button "
" to enter.
4. Select the parameter "tEr"using "
"and "
set
press the button "
" to enter.
5. Select the parameter "dIFI"using "
set
press the button "
" to enter.
6. Change the value using "
"and "
" buttons and press the
set
button "
" to confi rm and exit.
esc
7. Press the button "
" three times to exit.
4.5.4
Restore default parameters (see fi g.1/2)
1.Turn the main swicth (QS) to "ON" and wait for the "OFF" visualiza-
tion.
esc
set
2.Press the buttons "
" "
" together to enter on the parameter
type "D"
3.Select the parameter "PAr"using "
"and "
set
press the button "
" to enter.
4. Select the parameter "P_nA"using "
set
press the button "
" to enter.
5. Select the parameter "dEF"using "
"and "
set
press the button "
" to enter.
6. Change the value "OFF" to "On" using "
set
and press the button "
" to confi rm and exit.
esc
7. Press the button "
" three times to exit.
" buttons and
" buttons and
"and "
" buttons and
" buttons and
"and "
" buttons and
" buttons and
"and "
" buttons
5 / 8