Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Relation of power range between the outlets
Guide aperture is based on the " Digital S or Digital SE " lamphead and the 50° reflector,
distance 1 m/3.3 ft and film ISO 100/21 DIN.
Digital 1200 RX
Scale
Ws
7.5
1200
6.5
600
5.5
300
4.5
150
3.5
75
2.5
37.5
Main Supply
While the MAINS SWITCH (3) is switched OFF (not illuminated), firmly push in the plug of the
original ELINCHROM mains cord (1).
Fuse
Standard type 5 x 20 mm, 16 AT (tempered). Before exchanging a blown fuse, switch off the unit
and remove mains cable. Depress and turn the fuse holder anti-clockwise 1/8th and remove it.
If the new fuse blows immediately upon reconnection return the pack to an ELINCHROM service
centre for a check-up.
(N.B. Check correct value of the fuse: 16 AT).
Overvoltage security
This unit is protected by security device.
Should the unit not work properly, due to a defective power component,
the security would instantly stop the charge.
The power pack requires a check up at a technical Elinchrom service.
Fuses for flashheads
Use only FAST BLOW FUSES, type 5 x 20 mm corresponding to the label on each flashhead.
Different modelling lamps require corresponding fuses. Slow blow fuses will not protect the
modelling lamp. The fast blow fuse will protect the triac of the modelling lamp circuit, the
lamp and therefore the flash tube.
Fuse
W
110V
200
2 AF
250
5 AF
300
5 AF
650
10 AF
Only use recommended fuse
f-stop
Scale
(128)
(90)
(64)
(45)
(32)
(22)
240V
2 AF
2.5 AF
2.5 AF
5 AF
Digital 2400 RX
Ws
8.5
2400
7.5
1200
6.5
600
5.5
300
4.5
150
3.5
75
Modelling
Lamp switch
f-stop
Power
(180)
1/1
(128)
1/2
(90)
1/4
(64)
1/8
(45)
1/16
(32)
1/32
Fuse
EN
9

Quicklinks ausblenden:

Inhaltsverzeichnis
loading

Inhaltsverzeichnis