WORK SEQUENCE
General information
Warm up time: 10 Minutes
Polyurethane Profile: Adjust 290°C mark
(min� 285°C, max� 300°C)
Polyester Profiles: Adjust 240°C mark
(min� 215°C max� 245°C)
TIPP: Check welding temperature from time to time
with temperature meter�
When changing the mirror, the temperature must be
checked
For difficult external temperature conditions increase
the welding temperature�
Method
In order to ensure a constant welding temperature, we
recommend to ensure that the belt is at room temper-
ature before commencing the welding procedure�
18