4. 5
Tolerance limits
The tolerance limits can also be set for good/not good measurement. If you activate the alarm and set up a valid
limit, the
icon will be displayed for values within the limit, the
icon for values that exceed the upper limit.
4.6
Zeroing
Press ZERO/▲ to clear the force gauge in Track mode, i. e. to remove the tare.
4.7
Hand-held or test stand operation
The force gauge is a portable instrument, which means that you can carry out measurements by holding the device
in your hands, or you can install the force gauge to a test stand to obtain more accurate measurement results.
There are 4 x M5 mounting screw holes at the back by means of which the force gauge can be fixed to a test stand.
4.8
Memory
Measurement results can be saved to the internal memory of the force gauge so that you can review or print them
later. Press the SEND/EXIT key to save measured values and the
4.9
Test method
During measurement, the device and the object to be measured must form a straight line.
icon for values below the lower limit and the
icon will be displayed.