Errorcodes
Code
Error Type
E1
Low battery voltage protection
E2
Fan over-current protection
E3
Compressor fault protection
(motor blockage or excessive
pressure in the refrigeration
system)
E4
Compressor fault protection
E5
Compressor control module over
temperature protection
E6
NTC fault (short circuit, broken
circuit)
Note: If the abnormal situation cannot be resolved by simple fault analysis,
contact our customer service hotline for assistance.
The box body surface
is producing light
condensation. When the
ambient air humidity
is > 75%, the air in the
water vapor encounters
lower temperature
which is liquefied on the
refrigerator shell and
condensed into small
water droplets.
Processing method
Charge the battery or turn down the
battery protection level.
Turn off the machine and leave it
for 10 minutes and then restart it; if
it appears again, please contact the
after-sales staff.
Turn off the machine and leave it
for 10 minutes and then restart it; if
it appears again, please contact the
after-sales staff.
Turn off the machine and leave it
for 10 minutes and then restart it; if
it appears again, please contact the
after-sales staff.
Place the refrigerator in a ventilated
place, turn off the machine and
leave it for 10 minutes before
restarting; if it appears again, please
contact the after-sales personnel.
Please contact the after-sales staff.
This is a normal
phenomenon. Dry with a
towel. Adjusting the high
refrigeration temperature
is conducive to reduce
the phenomenon of
condensation.