WARNING
Overdue maintenance can lead to fire.
WARNING
Always turn the machine OFF and unplug it from the mains
socket before carrying out the work described below. First read
the maintenance instructions at the beginning of this manual.
9.1
Periodic maintenance
The maintenance work indicated with a [1] in the table below may be
carried out by the user; all other work may only be carried out by
qualified personnel. Before performing maintenance, check status of the
unit(s) in the Air Safety Portal. Then perform visual check and check noise.
Action
Clean the outside of the machine with a mild detergent.
Clean the inside of the machine and remove the dust/
grease from the filter compartment.
Clean or replace the bag filter and/or compact filter(s).
Check the filter for damage.
9.2
Replacing the filter
Replace the filter:
in the event of damage
as soon as the extraction capacity becomes inadequate
Because the nature and degree of contamination greatly depend on factors
such as the exact application, humidity level, intensity of use etc., you will
have to determine the necessary replacement frequency based on
experience. Nevertheless, the filter should be checked regularly (every two
weeks to every two months).
WARNING
Contaminated filters often contain dust and dirt particles that
can pose a threat to health when inhaled. Therefore, wear a
proper, approved face mask when cleaning the filter.
9.2.1 Removing the filter
Switch the machine off with the main switch (fig. 4).
Remove the brackets and open the grille.
Take the filter out
9.2.3 Replacing the filter
Bag filter
10
TROUBLESHOOTING
10.1
Malfunctions DUST FREE INDUSTRIAL 30/60
Problem
Motor does not start
Motor hums, but does not run
Motor stops on its own
Insufficient extraction capacity
Every 6
months
X[
]
1
X[
1
]
X[
]
1
Possible cause
No mains voltage
Main switch defective
Fuse defective
PCB defective
Motor is stuck
Motor defective
Fan dirty
Filters dirty
Suction side air leak
If the machine does not work or does not work correctly, consult the
following checklist to see if you can solve the problem yourself. If not, seek
the assistance of qualified personnel.
WARNING
Always check first whether the fault is mechanical or electrical.
Work on and repairs to the electrical system may only be carried
out by trained, authorised service technicians.
Always turn the machine OFF (use the main switch, fig. 4) and disconnect the
power supply before carrying out any repairs. First read the repair
instructions at the beginning of this manual.
11
ORDERING SPARE PARTS
Send your order to your supplier and always provide the following
information:
- product name, supply voltage and serial number
(see identification plate)
- item number of the part concerned
- part name
- quantity
Remedy
Check the mains voltage
Repair or replace the main switch (by Euromate)
Replace the fuse (by Euromate)
Replace the PCB (by Euromate)
Free/clean the motor (by Euromate)
Repair or replace the motor (by Euromate)
Clean the fan (by Euromate)
Replace the filters. See chapter 8.2.
Check or replace the sealing material.
User Manual Dust Free Industrial 30/60