EN
DECLARATION OF "CE" CONFORMITY
TOPP S.r.l.
via L. Galvani, 59
36066 Sandrigo (VI)
ITALIA
declares that the electric device
denominato: MICROWAVE SENSOR
models: WS2
Serial number: see data place and "CE" marking applied on
the equipment
complies with the requirements of the following directives:
2014/35/EU
Low Voltage Directive
2014/53/EU
R&TTE Directive
2011/65/EU
The RoHS Directive
and, besides, it declares that the following harmonized standards
have been applied:
EN50581
Date: Sandrigo, 10/05/2014
Matteo Cavalcante .....................................................
2
TECHNICAL DATA
MODEL
VOLTAGE SUPPLY
POWER
PROTECTION CLASS
OPERATING TEMPERATURE
3
RATING PLATE AND "CE" MARKING
The "CE" marking certifies the compliance of the
infrared sensor with the essential safety and health
requirements foreseen by the product European
Directives.
The rating plate is an adhesive plate in polyester, silk-
screen printed in black, applied externally on the
infrared sensor. The plate bears in readable and
indelible way the following data:
Logo of the manufacturer
"CE" marking
Type and model
Voltage (V) and
power (W)
EN
WS2
For the installation of the microwave sensor,
proceed as follows:
Fig.2 If the installation is on the opposite side of the
automation, it is necessary to pass the cable to the
opposite side of the door being careful that it does
not interfere with the door opening (you can
possibly drill the wall with a suitable 5 mm tip), and
that it comes out of the other side for at least 70 cm.
Fig.3 With a suitable drill with 4 mm tip make a hole
on the wall centre line above the door.
Enter the two provided dowels 4x20 for light fittings
into the holes. If the sensor is located on the
opposite side of the automation, run the sensor
cable along the door upper frame, place it into the
provided hole of the sensor fitting base making it
come out for at least 70 mm.
Fix definitely the mounting base with two screws AF
TSP d3x25.
Fig.4 Put the sensor and the electronic board on
the fixing basis.
For the cable wiring, if the microwave sensor is
used with the V1- V1E automatic door, make sure
that there is the bridge between terminal No. 2
and terminal No. 3, then refer to Fig. 5 - 6.
When using the microwave sensor with other
automatic doors , follow the instructions about the
terminal shown in Fig. 4, ref. A, taking care to
remove the above bridge.
WS2
The sensor signal power can be adjusted by acting
12/24 V
on the proper trimmer on the electronic board (Fig.
0,3W
5);
by turning the trimmer to the right , the sensor's
IPX0
detection area increases, by turning it to the left it
0°C ÷ 50°C
decreases.
You can also adjust the signal range by pointing the
sensor appropriately ( Fig. 7)
After completing the adjustment, put the lid
cover.
The microwave sensor is maintenance-free. In case
of a device malfunction, please contact our
Customer Service.
The demolition of the feeding unit must occur in
compliance with the laws in force on enviroment
protection. Differentiate the parts making up the
feeding unit according to their different material type.
Protection degree (IP)
Serial number
4
INSTALLATION OF THE SENSOR
5
REGOLATION OF THE SENSOR
6
MAINTENANCE
7
DEMOLITION